![GS Chromalox 4081 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/gs/chromalox-4081/chromalox-4081_installation-and-operation-manual_2274774054.webp)
46
CLOCK CONFIGURATION SUB-MENU SCREENS
Date Format
w
The format used for all displayed dates: dd/mm/yyyy (Day / Month / Year) or
mm/dd/yyyy (Month / Day / Year). – Recorder versions only.
Set Date
w
Set the internal clock Date – Entered in the format defined by Date Format
screen. – Recorder versions only.
Set Time
w
Set the internal clock Time. - In hh:mm:ss (Hours : Minutes : Seconds) format.
– Recorder versions only.
Note: Clock settings cannot be changed when the data recorder is active.
DISPLAY CONFIGURATION SUB-MENU SCREENS
Language
Select English or the alternate local language. The alternate language is se-
lected at time of order, but can be changed later using the PC software.
Enable Custom Display
Mode
Enables/disables the Custom Operation Mode, if configured. The screens
seen in this mode are configured using the PC configuration software.
Read Only Operation
Mode?
Allows Operation Mode to be Read/Write or Read-Only where screens can be
seen but the values cannot be changed.
Display Color
From: Red only; Green only; Red to Green on Alarm or Green to Red on Alarm;
Red to Green if Output Latched or Green to Red if Output Latched.
Invert Display
Standard or Inverted display image.
Display Contrast
Screen contrast (10 and 100) to improve clarity. 100 = maximum contrast.
Loop 1 Trend Sample
Interval
The Interval between the displayed values on the loop 1 trend graph. From:
Every 1; 2; 5; 10; 15; 30 Seconds, or 1; 2; 5; 10; 15; 30 Minutes. -
Independent from the loop 2 trend graph and data recorder sample rates.
Loop 1 Trend View Mode
The data to display on the loop 1 trend graph. From: Process Value only, PV
(solid) & SP (dotted) at sample time, or the Max & Min PV between samples
(candle-stick graph). Alarm active indication is always shown at the top of
graph.
Loop 2 Trend Sample
Interval
The Interval between the displayed values on the loop 2 trend graph. From:
Every 1; 2; 5; 10; 15; 30 Seconds, or 1; 2; 5; 10; 15; 30 Minutes. - Independent
from the loop 1 trend graph and data recorder sample rates.
Loop 2 Trend View Mode
The data to display on the loop 1 trend graph. From: Process Value only, PV
(solid) & SP (dotted) at sample time, or the Max & Min PV between samples
(candle-stick graph). Alarm active indication is always shown at the top of
graph.
Operator Visibility
Extra parameters can be made visible/adjustable in Operation Mode from:
Profile Control; Recorder Start/Stop; Recorder Status; Loop 1 & 2 Setpoint
Select; Loop 1 & 2 Auto/Manual Select; Loop 1 & 2 Control Select; Loop 1 & 2
Trend View; Loop 1 & 2 Setpoint Ramp Rate.
See Operator Mode lists.
Содержание Chromalox 4081