12
4.4 Technical data
4.4.1 Complete pump unit
Dimensions:
See section
Weight:
See section
Sound pressure level
The sound pressure level was measured without a silencer
1 metre away from the unit.
4.4.2 Pump
Permitted flange forces and torques
Fig. 10
Flange forces and torques
*
Σ
F and
Σ
M are the vector sums of the forces and torques.
If not all loads reach the maximum permissible value, one of the
values is allowed to exceed the normal limit. Contact Grundfos for
further information.
4.4.3 Engine
Type:
4-stroke diesel engine.
Performance:
See section
.
Speed:
See section
.
Weight:
See section
.
Diameter exhaust gas line:
See section
.
Discharge heat exchanger:
Amount of oil:
See section
.
Type of oil:
API-classification CF4.
Viscosity: 15 W-40.
Oil pressure:
See section
.
Amount of cooling liquid:
See section
.
Cooling liquid:
Mixture of 50 % coolant and
50 % water.
Coolant:
Ethylene/glycol-coolant according
to ASTM D4985.
Cooling water temperature:
71 to 93 °C.
Fuel filling quantity:
See section
.
Fuel type:
Diesel.
Permissible counter-pressure exhaust gas: 0.075 bar.
Pump type
Engine type
Sound pressure
level
Fire NKF 50-200
JU4H-NL14
97.2 dB(A)
Fire NKF 65-200
JU4H-NL14
97.2 dB(A)
Fire NKF 80-200
JU4H-NL14
97.2 dB(A)
JU4H-NL24
97.2 dB(A)
Fire NKF 80-250
JU4H-NL24
97.2 dB(A)
JU4H-NL34
98.1 dB(A)
Fire NKF 150-400
JU4H-NL50
98.6 dB(A)
JU6H-NL30
99.2 dB(A)
JU6H-NL50
99.2 dB(A)
JU6H-NL60
99.4 dB(A)
JW6H-NL30
100.3 dB(A)
Fire NKF 150-500
JU6H-NL60
99.4 dB(A)
JW6H-NL30
100.3 dB(A)
JW6H-NL40
101.4 dB(A)
Note
The dimensions of the silencer delivered from
factory are designed to meet the sound pressure
level requirements at the installation site.
The site or the required sound pressure level
must therefore be specified when placing the
order.
Warning
The sound pressure level when the engine is
running is >70 dB(A). Hearing protection must
therefore be worn when working on or near the
engine.
TM0
4
562
1
3
6
0
9
Grey cast iron
Diameter
DN
Forces
[N]
Fy
Fz
Fx
Σ
F*
Horizontal pump,
z-axis, discharge port
50
525
473
578
910
65
648
595
735
1155
80
788
718
875
1383
150
1575
1418
1750
2748
200
2095
2600
2100
4055
Horizontal pump,
x-axis, suction port
65
735
648
595
1155
80
875
788
718
1383
100
1173
1050
945
1838
200
2345
2100
1890
3658
250
2980
2700
3340
5220
Grey cast iron
Diameter
DN
Torques
[Nm]
My
Mz
Mx
Σ
M*
Horizontal pump,
z-axis, discharge port
50
350
403
490
718
65
385
420
525
770
80
403
455
560
823
150
613
718
875
1278
200
805
928
1138
1680
Horizontal pump,
x-axis, suction port
65
385
420
525
770
80
403
455
560
823
100
438
508
613
910
200
805
928
1138
1680
250
1260 1460
1780
1680
Caution
During the initial running time, use "John Deere
Break-in" oil (TY22041) for refilling.
Caution
Never use conventional engine vehicle coolants.
They can damage the engine due to their high
silicate content!
Note
The size of the fuel tank allows the pump unit to
operate for six hours without interruption.
Содержание Fire NKF 150-400
Страница 1: ...Fire NKF diesel GRUNDFOS INSTRUCTIONS Installation and operating instructions...
Страница 97: ...97 10 1 a 5 1 4 b c d 4 5 1 e 2 a 4 5 1 b 5 1 4 c d e f g h 3 a b 4 a b c 5 a b 4 5 1 c d 5 1 9 e...
Страница 99: ...99 11 Grundfos Grundfos 12 13 Fire NKF 14 1 2 Grundfos Grundfos Grundfos...
Страница 129: ...129 30 Z tka plniaceho otvoru paliva 31 Olejov erpadlo skryt Pol S iastka...