Reverse osmosis system
GENO-OSMO-X
Order no. 134 750 927-inter Edited by: phar/mrie G:\BA-750927-inter_134_GENO-OSMO_X.docx
70
H Maintenance
1 | Basic information
In order to guarantee the reliable function of the systems over a
long period of time, some maintenance work has to be per-
formed at regular intervals. All regulations and guidelines which
apply at the installation site must be strictly adhered to.
Check the quality and the system volume flows every day.
Maintenance has to be performed by Grünbeck’s technical
customer service/authorised service company or a specialist
company. Maintenance is subject to the load but at the latest
has to be performed once a year.
An operation log and the corresponding test log must be kept
in order to document the maintenance work performed.
Note:
A maintenance contract ensures that all the required
maintenance work will be performed in due time.
The maintenance work performed must be documented in the
checklist, refer to appendix "Operation log".
2 | Inspection (functional check)
You may perform the daily inspections yourself.
Please refer to the following summary for the tasks to be per-
formed within the framework of an inspection.
Summary: Inspection work
Determine the feed water hardness (inlet).
(Water test kit "Total hardness“)
Determine the permeate quality. Either at the display if a con-
ductivity monitoring device is installed or by means of a man-
ual conductivity meter
Read the recovery
Take the remaining time of the service interval into account
Chapter F-2.2 Read operating state.
In case the remaining time of the service interval is < 30
days, notify Grünbeck's technical customer service about the
impending service.
Note:
Minor deviations are normal and cannot be prevented
technically. In case of considerable deviations from the standard,
notify Grünbeck's technical customer service/authorised service
company.
Make sure that there are no leakages from the system to the
drain; the feed water solenoid valve is not tightened; visible at
the display (fig. F-2). In this state, no water must creep to the
drain.