Reverse osmosis system
GENO-OSMO-X
Order no. 134 750 927-inter Edited by: phar/mrie G:\BA-750927-inter_134_GENO-OSMO_X.docx
62
Continuation table G-1: Warnings
This is what you observe
This is the cause
This is what to do
W024
Text displayed for prog. fault
signal input
Signal is pending at the pro-
grammed fault signal input. As re-
sponse “warning” is programmed.
Remedy the cause of the pending
signal.
W025
Battery
Buffer battery on basic circuit
board (stage 1) defective.
Notify Grünbeck’s technical cus-
tomer service/authorised service
company.
W026
Warning preserving agent
Indication during start-up.
Refer to chapter E.
W027
Battery 2
Battery on basic circuit board
(stage 2) defective.
Notify Grünbeck’s technical cus-
tomer service/authorised service
company.
W028
Service due
W029
Service AVRO
Only in case of AVRO
pre-treatment:
AVRO treatment modules have to
be replaced soon.
Notify Grünbeck’s technical cus-
tomer service/authorised service
company.
W030
Minimum pressure
Pressure switch for minimum pres-
sure 1 CP1 has detected low water
pressure in the inlet.
Subsystem GENO-OSMO-X was
stopped and automatically restarts
after a short period of time (>>
here, an acknowledgement is not
required but feasible).
Following the last, unsuccessful
start attempt, the GENO-OSMO-X
stops and indicates the error "low
pressure" (here, an acknowledge-
ment is required).
Release water supply for
GENO-OSMO-X.
Notify Grünbeck’s technical cus-
tomer service/authorised service
company.
W031
Time for first permeate ex-
ceeded
The quality of the first permeate is
still too bad after expiration of the
set time for first permeate.
Check in the customer service menu
whether the limit value for the con-
ductivity of the first permeate is too
high or whether the time for the first
permeate was set too short.
W033
Communication error
softening
The bus connection to the inter-
connected subsystems water sof-
tener WE-X resp. pressure booster
system DEA-X is disturbed.
If necessary, restore the power sup-
ply of the respective subsystems.
Check bus wiring and restore, if nec-
essary.
W034
Communication error
residual hardness
W035
Communication error EDI
W036
Communication error
pressure booster
Содержание GENO-OSMO-X