Reverse osmosis system
GENO-OSMO-X
Order no.
134 750 927-inter Edited by: phar/mrie G:\BA-750927-inter_134_GENO-OSMO_X.docx
37
2.2 Info level of GENO-OSMO-X
If the subsystem features an ON/OFF function such as the re-
verse osmosis system OSMO-X, the Info level has an ON/OFF
button, too: Green = subsystem ON, Red = subsystem OFF. With
the Home button, you may return to the Home screen. By press-
ing on the illustration, you may access the submenu.
The following information is stored in the Info level of the OSMO-X
(can be accessed via arrow keys ^/v):
Operating mode
(locked / flushing / manual operation / automatic)
Permeate flow [l/h]
Current set value for permeate capacity [l/h]
Permeate conductivity [µS/cm]
Permeate recovery [%]
Water temperature [°C]
Service in [d]
AVRO RO1 B5 (only in case of AVRO pre-treatment) [h]
Concentrate to drain [l/h]
Concentrate recirculation [l/h]
Permeate pressure (only for Online version) [bar]
AVRO RO1B5 treatment current
(only in case of AVRO pre-treatment) [mA]
Output of regulating valve RO1V3 [%]
Output of regulating valve RO1V2 [%]
Conductivity of inlet and concentrate (only if optional conduc-
tivity measurement is available) [µS/cm]
Feed water flow [l/h]
Feed flow [l/h]
Analogue signal output to frequency converter [%]
Home button
Operating mode, current measuring values
Access to the
GENO-OSMO X
menu
ON/OFF button