66
Continuation table G-2: Troubleshooting
This is what you observe This is the cause
This is what to do
E103:
Text displayed at prog.
fault signal input
Signal is pending at the pro-
grammable fault signal input.
The reaction is programmed
to "error".
Remedy the cause of the pend-
ing signal.
Correct the programming of the
system reaction, if necessary
(refer to chapter F-4.2).
E104:
Error GENO-tronic
Operating element of the con-
trol unit defective.
Notify Grünbeck’s technical cus-
tomer service/authorised service
company.
E107.
Error
temperature sensor
Temperature sensor of the
permeate conductivity meas-
uring cell defective or short-
circuit at the conductivity
measuring cell
Notify Grünbeck’s technical cus-
tomer service/authorised service
company.
E108:
Error HP pump
RO1P2
Frequency converter of high-
pressure pump signals an er-
ror.
Flip the GENO-OSMO-X control
unit towards the front. Report
the error message of the fre-
quency converter to Grünbeck’s
technical customer service/au-
thorised service company.
E110:
R01V1 does not close
V1 does not close, probably
due to impurities or a defec-
tive valve.
Clean R01V1. Replace solenoid
valve.
E111:
Membrane degassing
Air flow is too low.
Check compressed air supply.
E113:
EH (water softener)
Error power failure
Power failure > 5 minutes.
If the power failure took longer,
start a manual regeneration to
be on the safe side. The water
flowing through the system in
the meantime, was not regis-
tered and the exchanger in oper-
ation might be overrun.
E114:
EH (water softener)
Error valve motor
The next step positon at the
control valve was not reached
within the required time.
If the error occurs again within 5
minutes after it was
acknowledged, notify
Grünbeck’s technical customer
service/authorised service com-
pany.
E116:
Error hard water
While one exchanger tank
has not yet been regener-
ated, the other is already ex-
hausted.
The error will acknowledge itself
as soon as a regenerated ex-
changer tank is available again.