Reverse osmosis system
GENO-OSMO-X
Order no. 134 750 927-inter Edited by: phar/mrie G:\BA-750927-inter_134_GENO-OSMO_X.docx
60
G Troubleshooting
1 | Basic information
There is a difference between warnings and errors:
Warning = the status line in the GENO-tronic operating ele-
ment is high-lighted in yellow and the signal contact of the
OSMO-X control unit (terminals 8/9) opens
Error = the status line in the GENO-tronic operating element
is high-lighted in red and the fault signal contact of the
OSMO-X control unit (terminals 7/9) opens
As long as the power supply is on and no warnings/errors are
pending, the signal contact and the fault signal contact are
closed.
For troubleshooting in general, also refer to chapter F-2.4.
Note:
A malfunction at one of the subsystems installed up-
stream, in general causes the shut-off of the subsystems in-
stalled downstream. Eliminating and acknowledging the malfunc-
tions generally provokes the disconnected subsystems to restart
automatically.
Even carefully designed and manufactured technical systems
that are operated properly, may experience malfunctions. Table
G-1 provides an overview of possible problems that may occur
during the operation of the systems and indicates the causes
and their elimination.
Note:
Grünbeck's technical customer service/authorised service
company definitely must be notified in case of warnings or mal-
functions that cannot be remedied with the information given in
tables G-1 and G-2! When contacting the technical customer
service, please indicate the system designation, serial number
and the error message displayed.