2016-11-16
401-406M
YP2425 and YP2425F
Troubleshooting
88
Press wheels
not
compacting
the soil as
desired.
Incorrect spring handle setting
Wheel stagger needs adjustment for
conditions
Insufficient row unit down force
Too wet or cloddy.
Wait until drier weather or rework ground.
Use of incorrectly shaped tire for your
conditions.
Wedge shaped wheels work best on narrow spacings and in wet
conditions. Round edge wheels work best in wider row spacings
and drier conditions.
Incorrect press wheel depth.
Reset press wheel depth, page 84.
Press wheel
or row-units
plugging
Planting conditions too wet.
Wait until drier weather.
Too much pressure on row-units.
Reduce down pressure on row-units.
Coulters set too deep, bring up excess dirt
and moisture.
Check coulter adjustment.
Backed up with planter in the ground.
Clean out and check for damage.
Failed disk bearings.
Replace disk bearings.
Disk blades worn.
Replace disk blades.
Scraper worn or damaged.
Replace scraper.
Air lines
plugging
between air
box and Y
splitters
Improper air hose routing.
With planter unfolded, hoses should form a gentle horizontal “S”
shape through the holders with no big sags.
Air leaks between manifold and splitters
Check for leaks and correct as needed.
Fan air flow too low.
Speed up fan. If already at 3800 rpm, increase airflow by
reducing butterfly valve angle, before increasing rpm.
Seed blowing
out of
Pro-Box door
area
Fan air flow too high.
Slow down fan. If already at or below 3000 rpm, set fan at
3800 rpm and use fan butterfly valve to reduce airflow.
Seal on top of airbox damaged or out of
adjustment.
Seal should be compressed approximately
1
/
2
inch when
hopper or box is installed.
Hydraulic
marker
functioning
improperly
Marker circuit set to Aux
Set Marker/Aux valve on wing to Marker. See page 48.
Air in lines or valves
Rephase Marker cylinders, then see “
Leaks in hose fittings or connections.
Check all hose fittings and connections for air or oil leaks.
Low tractor hydraulic oil level.
Check tractor hydraulic oil level.
Loose or missing bolts or fasteners.
Check all bolts and fasteners.
Needle valve plugged.
Open needle valve, cycle markers slowly and reset needle
valve. See page 56.
Needle valve(s) in sequence valve plugged.
Open needle valves, cycle markers slowly and reset needle
valves. See page 56.
Wing Fold Switch ON
Turn Wing Fold switch OFF
Marker disk
does not
mark
Marker folding linkage does not have enough
slack to allow marker disk to drop into field
depressions.
Marker Chain Length Adjustment
Marker disc needs adjustment
Increase disc angle. If still no mark, reverse marker disk to pull
or throw dirt.
Hydraulic
Hitch Won’t
Stay Raised
Bypass valve is open at hitch
Close valve.
Problem
Cause
Solution
Содержание YP2425
Страница 2: ...Table of Contents Index Table of Contents Index...
Страница 164: ...2016 11 16 Table of Contents Index 401 406M YP2425 and YP2425F Table of Contents Index 160...
Страница 165: ...Table of Contents Index Table of Contents Index...
Страница 166: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402...