YP2425 and YP2425F
Adjustments
61
2016-11-16
401-406M
John Blue Ground Drive Pump
Refer to Figure 70
With newer Type 2 fertilizer systems, the pumps
are
driven by a ground contact wheel
. Fertilizer rate is
independent of seed rate. Fertilizer coarse rate is set by
a driving sprocket
on the ground drive assembly, and
fine rate is adjusted at the setting hub (dial)
on the
pump.
Equipment Damage/Material Loss Risks:
The ground drive contact wheel and chain system will operate
whenever the planter is lowered and in motion. If planting
without fertilizing, the pump must not be allowed to run dry.
Disconnect the chain or remove a sprocket.
Note:
When a Type 3 fertilizer system is installed, the
pump is mounted at the source (not on the
planter), usually on a tank cart.
For sprocket and dial settings, refer to the Seed Rate
manual.
Hypro Ground Drive Pump
Refer to Figure 71
With older Type 2 fertilizer systems, the pumps
are
driven by a ground contact wheel
. Fertilizer rate is
independent of seed rate. Fertilizer rate is set by
driving
and driven
sprockets on the ground drive
assemblies.
Equipment Damage/Material Loss Risks:
The ground drive contact wheel and chain system will operate
whenever the planter is lowered and in motion. If planting
without fertilizing, the pump must not be allowed to run dry.
Disconnect the chain or remove a sprocket.
Note:
When a Type 3 fertilizer system is installed, the
pump is mounted at the source (not on the
planter), usually on a tank cart.
For sprocket settings, refer to the Seed Rate manual.
Figure 70
John Blue Pump
Sprocket and Dial
28416
2
4
3
1
1
2
3
4
Figure 71
Hypro Pump Sprockets
26319
2
3
5
1
1
2
3
5