2016-11-16
401-406M
YP2425 and YP2425F
Appendix R - Row-Pro™
152
Sensitivity Adjust:
Determines how responsive the
Controller is to input from the DPLCM. The range is from
-10 to +10. Zero (0) is the average setting. Going below 0
decreases the reaction time. Going above 0 increases
the reaction time.
Disable Down Pressure Modules:
Modules interfacing
with feedback sensors can be independently disabled so
that down pressure to rear and/or front row units are not
monitored or controlled. Modules that have been
disabled are ignored by the system and will not report
down pressure data or react to soil conditions.
(The IntelliAg
®
screen shows both row modules
enabled
. An unchecked box indicates disabled.)
If a section fails, that individual section can be turned on
and off to locate the problem.
Refer to Figure 157
Reset Offset Value:
Resetting Offset Values clears
previous down pressure readings and resets values to
zero.
1.
At Main WORK SCRN press NEXT PAGE button.
2.
Press MODULE CFG button.
3.
At Module Configuration screen, press
DPRESS SET.
4.
At the Down Pressure Setting screen press OK to
clear values.
IMPORTANT:
The implement must be lifted and the
implement lift switch in the up state before the OK
button appears and values can be cleared.
Note:
Make sure side depth wheels are all in the
lowered position so there is no tension on the
load cell. Values other than OFF or 1-6 mV may
indicate stuck side depth wheels. If the reading
is 0 mV, there may be a problem with load cell
grounding. See “
, page 178.
Note:
Initial Setup:
Zero out the load cell reading.
Figure 156
IntelliAg
®
Screen
36545
3
Figure 157
IntelliAg
®
Screen
36551