YP2425 and YP2425F
Maintenance and Lubrication
97
2016-11-16
401-406M
Finger Set Installation Instructions
Installation Steps
Great Plains recommends having the meter service
performed by a recognized professional repair facility,
such as a certified Meter Max representative. Improper
servicing will result in
reduced
meter performance.
If you choose to service them yourself, follow these
procedures when installing the finger sets.
Refer to Figure 133
11. Be sure the belt is oriented as shown in Figure 133.
12. Slide the finger set over the shaft and rotate
clockwise until it sits against the backing plate.
Note:
You will hear a click.
13. Firmly press the finger set against the backing plate
while tightening the nut.
14. Tighten the nut until contact is made between the nut
and the finger set. Turn
1
/
4
to
1
/
2
flat (
1
/
24
to
1
/
12
of a
turn) (a flat is one of the six sides of the nut) after
contact is made. This equals about four inch- pounds
of torque on the nut.
15. Place the slotted nut cover on and carefully align the
slotted nut cover with the shaft hole. Insert the cotter
pin.
16. Rotate the finger set clockwise and make sure the
fingers open and close properly. Fingers should be
closed at the 8:00 to 2:00 position (exit hole) and
open at the 2:00 to 8:00 position.
Annual Maintenance
Finger sets should be inspected on an annual basis.
After cleaning, carefully inspect the fingers and springs
for wear or other abnormalities that may develop.
Excessive wear may disrupt singulation performance.
Precautions
1.
Make sure the finger set is properly torqued against
the backing plate. Improperly torqued finger sets
may disrupt seed singulation.
2.
Avoid seed treatments, additives, and other
chemicals when possible. They can cause meter
performance problems, premature wear to meter
parts, and may cause undesired chemical reaction or
deterioration to the finger sets. Always use Precision
Planting or Great Plains graphite when using seed
treatments, See “
Graphite from other sources may cause premature
wear.
3.
Always pay attention to your seed monitor, pay
attention to your operating manual, and monitor the
amount of seed you are planting compared to your
expectations. Always investigate abnormalities!
Figure 133
Finger Pickup Meter
22507
Содержание YP2425
Страница 2: ...Table of Contents Index Table of Contents Index...
Страница 164: ...2016 11 16 Table of Contents Index 401 406M YP2425 and YP2425F Table of Contents Index 160...
Страница 165: ...Table of Contents Index Table of Contents Index...
Страница 166: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402...