5-5
Chapter 5 Detailed Settings
Setting the Condition Priority
Select "MANUAL" or "PROGRAM" for the condition of the tool.
MANUAL:
Cutting conditions sent from the software are invalidated while the conditions set with the
operation panel are made valid.
PROGRAM:
The cutting conditions can be changed from both the operation panel and the software making it
possible to overwrite the setting with new cutting conditions at any time.
1.
From the "MENU" screen, open the "TOOL 1/2" screen.
2.
For the condition priority, select "MANUAL" or "PROGRAM".
Setting the Distance Adjustment
Corrects the displacement by the length of the cutting line that occurs depending on the type and thickness
of the media being used. The value for distance adjustment is input as a percentage for the amount of
displacement for the length of the line For example, if +0.1% is set as the correction value, the length of a line
that is 1 m (1000 mm) will increase by 1 mm (= 1000 × 0.1%) and become 1001 mm.
This distance adjustment can be configured for each CONDITION NO.
1.
Touch the
(CONDITION) on the "HOME"
screen to open the CONDITION NO.
setting screen.
2.
Select the CONDITION NO. to set by using
the " " and "
" buttons and touch the
(PAGE) button to proceed to the next page.
3.
Touch the "DISTANCE ADJUST" button.
4.
Select "ON" or "OFF" for "DISTANCE
ADJUST".
When "ON" is selected, it will be possible
to input a value in the "DISTANCE ADJUST
X" box and "DISTANCE ADJUST Y" box.
5.
Touch the "DISTANCE ADJUST X" box.
6.
Input the value for distance adjustment
and confirm the input with the (Confirm)
button.
7.
Similarly input "DISTANCE ADJUST Y".
Содержание CELITE-50
Страница 1: ...USER S MANUAL CE LITE 50 UM 151...
Страница 2: ......
Страница 10: ......
Страница 22: ......
Страница 78: ......
Страница 101: ...5 23 Chapter 5 Detailed Settings 3 Select ON or OFF for WIDTH DETECTION...
Страница 112: ......
Страница 116: ...A 4 Appendix A 3 Appearance Drawing 164 784 227 173 400 Units mm Dimension error 5 mm...
Страница 118: ...A 6 Appendix 3 PIECES Previous Page HOME SELECT FILE...
Страница 119: ...A 7 Appendix TOOL ARMS MODE 1 MODE 2 MODE 3 CHECK MARK SCAN SENSOR OFFSET ADJ Next Page MENU...
Страница 120: ...A 8 Appendix INTERFACE ADVANCE TEST Previous Page AREA MEDIA MENU...
Страница 127: ......
Страница 128: ......