310531
15
Installing Control Assembly Hardware
Verifying Ground Continuity
Verify ground continuity between:
true earth ground and the panel ground lug
the application device and the robot
the metering valve and the robot
Connect PrecisionFlo Control Assembly
to Power Source
You must connect the PrecisionFlo control assembly to
a power source.
WARNING
ELECTRIC SHOCK HAZARD
Do not connect the PrecisionFlo control
assembly to a power source unless you
are a trained electrician. Failure to fol-
low standard procedures or to observe the neces-
sary precautions could result in serious bodily injury
or equipment damage.
CAUTION
If power and grounding connections are not done
properly, the equipment will be damaged and the
warranty will be voided.
NOTE: Have a qualified electrician connect the Preci-
sionFlo control assembly to a grounded electrical
source that has the required service ratings.
Power Requirements for Control Assembly 918463
PrecisionFlo:
918463
with
optional
617474
with
optional
617497
Vac:
120
220
100
Hz:
60
50
50
Phase:
1
1
1
Full Load
Amps:
13
8
16
Circuit Breaker
20
10
20
Power Requirements for Control Assembly 918644
918644
VAC:
Hz:
Phase:
Full
Load
Amps
120
60
1
13.3
To connect the control assembly to the electrical
source:
1.
Create an opening in the enclosure.
2.
For 918463 or 918644, connect electrical power to
L1 (hot) and L2 (neutral) at main switch inside the
control assembly enclosure. (See Fig. 8).
3.
Use NEMA 4 cord grip to seal the area where
wires enter the enclosure.
Checking Resistance Between the Control
Assembly and the True Earth Ground
WARNING
FIRE, EXPLOSION, AND ELECTRIC
SHOCK HAZARD
To reduce the risk of fire, explosion, or
electric shock, the resistance between
the supply unit components and true
earth ground must be less than 0.25
ohms.
Have a qualified electrician check the resistance
between each supply system component and the true
earth ground. The resistance must be less than
0.25 ohms. If the resistance is greater than 0.25 ohms,
a different ground site may be required. Do not operate
the system until the problem is corrected.