310531 41
Fine Tuning
The procedures in this section are for fine tuning the
PrecisionFlo system when there are minor or tempo-
rary changes to the material characteristics.
Setting Scale Analog In
The Scale Analog In allows the operator to uniformly
increase or decrease the dispense rate throughout the
entire cycle without having to reprogram the robot.
To change the dispense rate, you must first determine
the percentage by which to increase or decrease the
material amount. The maximum adjustment permitted
is
±
10% of the initial value. Only values between 90%
and 110% will be accepted. Larger changes must be
made in the robot controller.
1.
On the control pendant:
HOME
SETUP
Scale Analog In
2.
You see:
––SCALE ANALOG IN––
Analog Input Scale
Factor=xxx%
Previous=xxx%
3.
Key in a number from 90 through 110 percent,
then press
[ENTER]
.
4.
Press
[HOME]
to return to the HOME screen.