310531 43
PrecisionFlo Module Operation
Starting the Module
To start the module, you (Fig. 30):
1.
Carefully inspect the entire system for signs of
leakage or wear. Replace or repair any worn or
leaking components before applying power.
2.
Turn on air and electrical power to the system.
3.
Turn on the main electrical disconnect (27) to
supply power to the PrecisionFlo module.
4.
The control pendant becomes active, showing first
a diagnostic message, that includes the software’s
version number, and then the Home menu.
5.
Turn on material pump.
6.
Push the MASTER START button (24) to turn on
power to the PrecisionFlo metering valve drive
circuitry. This lights the CONTROL ON indicator.
7.
If this is the first time the module has been started,
or you want to configure the software, go to Con-
figuring the PrecisionFlo Module on page 23.
Restarting the Module
If the module is on, but the CONTROL ON indicator on
the control assembly is not lit:
1.
Check the control pendant to see if a fault has
occurred. If a fault has occurred, you must clear
the fault before restarting the PrecisionFlo module.
Press
[F1]
to clear the fault.
2.
Press MASTER START/STOP RESET, (24) in
Fig. 30, on the control assembly.
3.
Choose AUTOMATIC dispense mode from the
HOME menu.