310531 79
Technical Data
Control Assemblies 918463 and 918644
Specifications
Weight
Approx. 110 lbs. (50.0 kg)
Dimensions
Control Assembly Enclosure, either:
For 918463:
30 inches (762 mm) high by 24 inches (610 mm)
wide by 10 inches (254 mm) deep
For 918644:
30 inches (762 mm) high by 25 inches (635 mm)
wide by 10 inches (254 mm) deep
Control Enclosure Footprint
5 feet (1.53 meters) by 5 feet (1.53 meters) including
space to allow control enclosure to be opened for
servicing.
Electrical Input Requirement
120 VAC
10%, Single Phase, 60 Hz.,
13.3 Ampere maximum current.
Circuit Breaker Rating
15 Amperes
Flow Command Input Signal Voltage
0–10 Volts D.C.*, minimum impedance 44 K
W
Flow Meter Option Output Signal Voltage
12–30 Volts D.C.
Control Assembly Storage Temperature
–25
°
to +55
°
C (–13
°
F to + 131
°
F)
* 4–20 mA. current mode flow control is available as a factory configuration of the control board. Contact Graco
Technical Assistance for information.