50 310531
Troubleshooting and Fault Recovery
Alarms
Table 7 — Alarm Code Table
Alarm
Code
Alarm
Name
Alarm Description
Causes
Solutions
2
Servo Drive
F
lt
Servo circuit condition at
d i
’
t
t
h d
Servo drive failure
Replace servo drive
Fault
servo drive’s output, or hard-
ware failure occurred on the
drive.
Motor short
Check that motor coil resistance is
10–13 Ohms.
drive.
Surge current to motor.
Decrease input step rate change and/or
limit maximum command signal.
4
Dispenser
Stop
There is no electrical power
to the MCR or servo drive.
Control assembly not acti-
vated at start up
Press MASTER START / STOP RESET
Control assembly not reacti-
vated after fault
SEALER STOP push button
pressed
CONTROL ON light not lit,
control assembly is off
Apply power to PrecisionFlo module,
then press MASTER START / STOP
RESET
5
Motor Over
Temperature
PrecisionFlo metering valve
linear motor temperature
h
d d 85
°
C
Servo drive short
Check for continuity b and –
outputs of servo drive
sensor has exceeded 85
°
C
(185
°
F).
Servo motor short
Insure that motor coil resistance is be-
tween 10 and 13 ohms
Excessive current to motor
over period of time
Monitor command signal outlet pressure
to determine operating range
Dirty motor heat sink
Clean motor surface
Poor motor ventilation
Increase air flow around motor
Failed transducer
Check transducer operation and ground-
ing. Replace if required.