74 310531
Appendix B. Configuring the Hand Pendant
You must set three parameters on the pendant: the
display contrast, baud rate, and data format.
During the set-up procedure, the pendant automatically
steps to the next parameter that needs to be config-
ured. To select a setting for a parameter, use:
[F4]
(30) to step down through the selections
[blank]
(31) to step up through the selections
[F3]
(29) to save a selection
To configure the control assembly’s pendant, follow the
procedure below.
Fig. 44
29
30
31
1.
Make sure the pendant and pendant cable are
connected to the control assembly.
2.
Remove power from the control assembly.
3.
Hold in the
[ENTER]
key and turn on power to the
Control Assy. The pendant displays the software
version number.
4.
Release the
[ENTER]
key and you see:
CONTRAST
5.
Adjust the display contrast.
a.
Step through the selections, until the display is
at the desired contrast.
b.
Save your selection. The pendant displays:
BR:XXXX
6.
Adjust the baud rate.
a.
Step through the selections until the display
shows
BR:9600
b.
Save your selection. The pendant displays:
DF: XXX
7.
Set the data format.
a.
Step through the selections until the display
shows:
DF: 8n1
b.
Save your selection.
8.
To complete the pendant set-up, press
[F3]
again.
9.
If you need to change a setting, turn the control
assembly’s power off, then return to step 1.