www.glp.de
48
KNV Dot and Line Quick Start and Safety Manual Rev. A
AC mains power
Warning!
Read ‘Safety’ starting on page 5 for important safety information
that you must understand before you install or operate the fixture.
Check that all cables and connectors are suitable for the installation
environment and application (see recommendations in ‘Avoiding damage’
on page 11).
Keep connectors sealed with their rubber caps at all times when not in use.
Do not allow any weight (in the form of cable runs, for example) to hang
from connectors, as this may affect their sealing ability and allow water to
enter connections.
KNV Dot and Line fixtures are supplied with DC power from the KNV PSU. This external
power supply unit is connected to mains power.
Connecting the KNV PSU to power
The AC mains power supply must include a connection to ground / protective earth. It
must be protected against ground / earth leakage and overload. The fixture’s internal
auto-sensing power supply accepts AC power at 100-240 V, 50/60 Hz. Do not connect
the fixture to power at any other voltage or to an external dimmer.
The KNV PSU does not have a power ON/OFF switch. Power is applied to the PSU as
soon as the power cable becomes live.
The KNV PSU has a 3-conductor Neutrik powerCON TRUE1 Mains IN power input socket
that accepts AC power from a TRUE1 female cable connector. Although TRUE1
connectors support hot-plugging, it is still good practice to shut down power to power
cables before connecting them to fixtures.
To connect the PSU to power:
If possible, shut down power to the power input cable.
Note the position of the keys and keyways on the TRUE1 power cable connector
and Mains IN socket and align them with each other. Insert the cable connector
into the socket and twist clockwise to lock.
Before applying power by energizing the power cable, check that nobody is
looking directly into the front of any fixtures that are connected to the PSU.
To disconnect the PSU from power, pull the latch on the cable connector outwards to
release it, then twist the connector counterclockwise and pull to remove it from the
socket.
Installing power connectors
It is possible to install a cord cap / mains power plug that is suitable for your local
convenience receptacles / mains power sockets on the supplied power input cable. If
you do this, check that the cord cap / plug is rated minimum 250 V, 16 A, that it has a