20 · GLOBE RM410 PISTON AIR MOTOR MANUAL| INCLUDING AUXILIARIES | ATEX Certified
To avoid slipping of the brake, two control valves are fitted on the brake which
may not be removed. Prior to the delivery the holding torque brake will be set by
the manufacturer. The customer/end-user has to inform GLOBE prior to the delive-
ry about the running pressure on which the motor will run. The brake will be set to
its maximum holding torque which is possible at this operating pressure. The two
control valves work in such way that the brake will always have the highest release
pressure after the motor is under pressure.
Operation
»
Before use always remove any sediments on
the surface of the brake before starting-up.
»
During operation be aware if unfamiliar
sounds or vibrations occur. Stop the unit
immediately and investigate the source.
»
Air quality should meet ISO 8573-1:2010
»
Bear in mind the maximum allowable torque
of the brake. Do not exceed as this may result
slipping and damage of the brake.
Allowable Radial Loads
RM110
RM210
RM310
RM410
RM510
RM610
N
445
890
1330
1330
6500
6500
LBF
100
200
300
300
1461
1461
Allowable speeds for brakes (RPM)
RM110
RM210
RM310
RM410
RM510
RM610
Continious
1950
1200
1800
1350
900
1100
Intermittent
0-2400
0-2400
0-2400
0-2000
0-2000
0-2000