2 · GLOBE RM410 PISTON AIR MOTOR MANUAL| INCLUDING AUXILIARIES | ATEX Certified
Contents
Warranty 3
Safety first
3
Checklist to comply to ATEX
4
Installation Motor & Valve
6
Mounting to construction
8
Air supply
9
Installation Brake
11
Mounting to construction
12
Operation Motor & Valve
13
Performance regulation
16
Operational principle HCV
17
Operational priciple RCV
18
Operation Brake
19
Specific Condition of Use
19
Operation Principle Brake
21
Load Adjustment
24
Maintenance Motor & Valve
25
Shutdown and long storage
26
Servicing 28
Maintenance Brake
38
Summary of the hazards with
protective means
40
Trouble shooting
41
Dimensions, Performances & Spare
Parts
42
Main dimensions RM410
42
Main dimensions RM410 + Brake
43
Performance RM410 + Brake
44
Main dim. RM410 + Brake + HCV
45
Main dim. RM410 + Brake + RCV
46
Performance RM410 + HCV/RCV
47
Spare Parts List RM410
48
Spare Parts List Parking Brake
49
Spare Parts List HCV
50
Spare Parts List RCV
51
Ordering code
52
ATEX Certification
54
CE Certification
58
Options & Accessories
60
APPROVALS
ATEX CERTIFICATION
In which:
II
2G
2D
Ex h
IIC
IIIC
T4
T5
T100°C
T135°C
Gb
Db
Ta
Equipment group II for use above ground
Category 2G for use in Zone 1 or 2
Category 2D for use in Zone 21 or 22
Protection by constructional safety “c” Gas
group IIC
Dust group IIIC
Temperature class T4
Tenoerature class T5
Maximum surface temperature 100°C
Maximum surface temperature 135°C
Equipment protection level Gb
Equipment protection level Db
Ambient temperature range
-20° ≤ Ta ≤ + 60°C
The GLOBE piston air motors and pneumatic
brakes are ATEX certified according to the
following (harmonized) standards:
EN-ISO80079-36:2016
EN-ISO80079-37:2016
The motors are marked with the following EX
marking:
-10° ≤ Ta ≤ + 60°C
The pneumatic brakes are marked with the
following EX marking:
II 2G Ex h IIC T5 Gb
II 2D Ex h IIIC T100°C Db
II 2G Ex h IIC T4 Gb X
II 2D Ex h IIIC T135°C Db X