14 · GLOBE RM410 PISTON AIR MOTOR MANUAL| INCLUDING AUXILIARIES | ATEX Certified
Do not run the air motor at high speeds with no load.
This will result in excessive internal heat that may cause motor damage.
STOP
Allowable speeds for motors (RPM)
RM110
RM210
RM310
RM410
RM510
RM610
Continious
1950
1200
1800
1350
900
1100
Intermittent
0-2400
0-2400
0-2400
0-2000
0-2000
0-2000
»
Check all connections before starting the air
motor. It is your responsibility to operate this
product at recommended speeds, loads and
ambient temperatures (-20°C to +60°C).
»
Check if the airline filtration and airline
lubrication is OK. The airline filter should be
drained and/or cleaned regularly and the
filter element examined for signs of clogging.
»
The maximum working pressure is 8 bar (120
PSI).
»
Clean surface of air motor unit thoroughly of
all dustproofing products, contaminants and
other impurities. Clean only with damp cloth.
»
Do not run the air motor at high speeds with
no load. This will result in excessive internal
heat that may cause motor damage.
»
The starting torque is less than the running
torque. The starting torque will vary depen-
ding on the position of the pistons in relation
to the air intake port when the motor is being
started.
»
During operation be aware if unfamiliar
sounds or vibrations occur. Stop the unit
immediately and investigate the source.
»
In case that the motor is exposed to high
vibrations, during operation and when not
in operation, please contact GLOBE. High
vibrations might lead to increased inspection
interval of the bearings.
»
The motor may run continuously at speeds up
to the rated running conditions shown in our
performance data sheets. In these sheets the
output power/torque is based on running
conditions with the actual pressure measu-
red at the motor port. Check the allowable
speeds below.
»
Advisable is to use an air dryer with set point
of 20 degrees Celsius below lowest ambient
temperature.