· 15
GLOBE RM410 PISTON AIR MOTOR MANUAL| INCLUDING AUXILIARIES | ATEX Certified
»
Axial loads must be kept to a minimum.
»
Max. radial load midway along shaft as shown in graph below:
»
Check intake filter and silencer after the first 100 hours of operation.
»
Clean filters and determine how frequently filters should be checked during future operation.
Airline filtration
»
Use a 64 micron air filter
»
The airline filter should be drained regular-
ly and the element examined for signs of
clogging.
Airline lubrication
»
The airline lubricator should be replenished
when needed and set to give the following
required drop rate/min:
»
For normal ambient temperatures 0°C to 32°C. Use oil with viscosity VG32.
»
For extremes of ambient temperature consult the manufactures.
The oil level in the motor casing must be maintained. The frequency of replenishment
will depend on the application and usage. The motor case should be drained and
refilled after 25 hours of initial running and every 200 hours thereafter or sooner if
found necessary e.g. (contamination of oil by water from the air line.)
STOP
Allowable Radial Loads
RM110
RM210
RM310
RM410
RM510
RM610
N
445
890
1330
1330
6500
6500
LBF
100
200
300
300
1461
1461
Drop rate/min
Motor
Continuous Operation
Intermittent Operation
RM110
3-4
6-8
RM210
4-5
8-10
RM310
5-6
10-12
RM410
6-8
12-16
RM510
6-8
12-16
RM610
8-10
16-20