background image

STM23C/24C Quick Setup Guide

Requirements

 

A small flat blade screwdriver for tightening the power connector (included).

 

A personal computer running Microsoft Windows XP, Vista, 7, 8, or 10 (32 or 64 bits).

 

ST Configurator™

 software (available at www.applied-motion.com).

 

CANopen programming cable (to host) (included)

 

CANopen daisy-chain cable (motor to motor)

 

RS-232 cable for connecting to a PC so you can configure the settings on your motor using 

ST Configurator™ 

(included)

 

For more detailed information, please download and read the STM23 Hardware Manual or STM24 

Hardware Manual, available at www.applied-motion.com/support/manuals.

To begin, make sure you have the following equipment:

Step 1 - Wiring

 

Wire the drive to the DC power source.

Note: Do not apply power until Step 3.

The STM23C and STM24C accept DC supply volt-

ages between 12 and 70 volts DC. If using an ex-

ternal fuse we recommend the following:
STM23C: 4 amp fast acting 
STM24C: 5 amp fast acting
See the STM23 and STM24 Hardware Manuals for more 

information about power supply and fuse selection.

 

Connect I/O as required by your application. 

Cable part number 3004-318 can be used for this purpose

 

Connect to the CAN network. 

Cable part number 3004-310 connects one mo-

tor to the next (daisy-chain) in the CAN network

 

Set Bit Rate and Node ID

Bit rate is set using a ten-position rotary 

switch. See Bit Rate table for settings.
Node ID is set using a combination of sixteen-position 

rotary switch and a software setting in 

ST Configura

-

tor

. The sixteen-position rotary switch sets the lower 

four bits of the Node ID. 

ST Configurator 

sets the up-

per three bits of the Node ID. Valid ranges for the Node 

ID are 0x01 through 0x7F. Node ID 0x00 is reserved 

in accordance with the CiA 301 specification.

Note: Node ID and Bit Rate are captured only af-

ter a power cycle or after a network reset command 

has been sent. Changing the switches while the 

drive is powered on will NOT change the Node ID un-

til one of these conditions has also been met.

 

Connect the RS-232 programming cable (in-

cluded) between the motor and the PC

920-0043 C

POWER CONNECTIONS

BIT RATE

I/O CONNECTIONS

NODE ID

CANopen/RS-232

CANopen/RS-232

STATUS LEDs

STM#1

STM #2

UP TO

127

AXES

Daisy Chain Cable

3004-310

Host Cable

3004-313

Host Device

Switch Setting

Resultant Bit Rate

0

1 Mbps

1

800kbps

2

500 kbps

3

250 kbps

4

125 kbps

5

50 kbps

6

20 kbps

7

12.5 kbps

8

n/a

9

n/a

Bit Rate Table

Отзывы: