45
Fryer Operation
GBF-50 Fryer
4.01.11 Controller Errors & Alarms
ERROR CODE DESCRIPTION (OLED Display)
PROBLEM
OPEN
DRAIN IS OPEN
Drain valve is open, or not completely closed. If equipped
w/basket lift, basket will be raised if it is down.
‐‐‐‐
CHECK OIL LEVEL, ENSURE VAT IS
FULL, IF FULL THEN PRESS
[START]
This is a secondary prompt to confirm oil level, which is
displayed after an
OPEN
drain error is cleared.
ER03
LOW OIL LEVEL – ENSURE VAT IS
FULL (Element/Add Level
Differential Warning)
The oil level is below the [ADD] line in the vat. Add fresh oil
until level is at [FULL] mark &
stir. Error remains in effect until
temperature differential is cleared.
ER06
LOW OIL LEVEL – ENSURE VAT IS
FULL – PRESS [START]
(Post ER03 Warning)
This is a secondary prompt to confirm oil level, which is
displayed after
LOW OIL ER03
error is cleared .
ER07
MAX ELEMENT TEMP – PRESS
[START] (Post Warning)
This is a secondary prompt displayed after
MAX
ELEMENT TEMP
ER19
error is cleared (element has cooled sufficiently).
ER13
OIL PROBE Error
Problem with the variable oil temp sensor.
Service required.
ER15
ELEMENT PROBE Error
Problem with the element temp sensor, typically attached
directly to heating element.
Service required.
ER17
ADD LEVEL PROBE Error
Problem with the
“Add Level”
sensor located at vat “ADD” mark.
Fryer without this sensor must have the ELMT
‐
ADD DIFF ENABLE
setting
OFF
in Factory Settings. Sensor cannot be bypassed.
Service required.
ER19
MAX ELEMENT TEMP Error
The maximum heating element temperature has been exceeded.
This is a safety device;
NEVER bypass this Probe
.
ER25
GUARD BAND EXCEEDED
Actual oil temperature deviates from setpoint by the Guard
Band value. Allow oil to cool or heat to be within range. Factory
default is 900
°
F ...
Typically, this error should not occur.
ER37
EEPROM Error
An error occurred while saving settings to the EEPROM.
Contact
Giles Tech Service (800.554.4537).
ER38
Internal ADC Error
The ADC (Analog
‐
to
‐
Digital Converter) chip that reads output
from thermocouples is not working. MCB1 board must be
replaced.
Contact Giles Tech Service (800.554.4537).
Conditions which can cause unsafe operation or damage to the unit
(open valves, low oil
level, max high temp, etc.)
cause the controller to halt operation, sound an alarm tone
and issue error codes/messages. Error codes are shown on the
Lower 7
‐
Segment Display
; error messages and prompts are shown
on the
Upper OLED Display
. Generally, heating elements are
disabled until error conditions have been corrected. Pressing the
[ALARM]
key silences the alarm tone, but does not clear an error.
Error codes are explained in the table below; details as to resolution
of errors are discussed in
Section 4.01.11.1
.
OLED
ALARM
7-Segment
Содержание GBF-50
Страница 10: ...x Safety GBF 50 Fryer ...
Страница 26: ...16 Overview GBF 50 Fryer 3 01 Baskets Optional Auto Basket Lifts 2 Hidden 1 4 3 ...
Страница 28: ...18 Overview GBF 50 Fryer 3 02 Control Panel 1 2 3 5 3 1 3 2 6 7 9 8 Switch position is plugged if not used 10 ...
Страница 32: ...22 Overview GBF 50 Fryer 3 04 Filter Pan Assembly Hold down Frame locking levers in Pan bottom 5 2 4 1 3 6 ...
Страница 38: ...28 Overview GBF 50 Fryer Notes ...
Страница 72: ...62 Fryer Operation GBF 50 Fryer ...
Страница 82: ...72 Troubleshooting GBF 50 Fryer ...
Страница 90: ...80 Parts List GBF 50 Fryer 7 05 Control Box Front behind Control Panel 2 5 1 6 4 3 7 8 10 11 ...
Страница 102: ...92 Parts List GBF 50 Fryer 7 11 Fry Vat Assembly 2 3 Top View 1 4 5 Bottom View 7 8 9 10 10 11 12 13 6 ...
Страница 104: ...94 Parts List GBF 50 Fryer 7 12 Filter Pan 3 1 5 4 2 9 7 10 6 8 A ...
Страница 106: ...96 Parts List GBF 50 Fryer Notes ...
Страница 110: ......