UK
UK
PRELIMINARY WARNINGS
Check that the gate structure is in conformity with the regulations in force and that leaf movement is linear without
friction.
Preliminary checks:
• Check that the gate structure is sufficiently robust. In any case, check that the weight and dimensions of the
gate fall within the limits of use of the operator;
• Check that the leaf can be moved manually without force (points of greatest friction) for the entire travel of the
gate during both opening and closing;
• Check that the area where the gearmotor will be fitted is not exposed to flooding. If so, install the gearmotor in a
position raised from the ground;
• If the gate is not a new installation, check the state of wear of all the components, repair or replace the
defective or worn parts and perform any other operations necessary.
The reliability and safety of the automated device is directly dependent on the condition of the gate structure.
1- Make the hole for the foundation plate respecting the dimensions
(2)
and arrange the plate according to the
closing direction of the gate
(3 - 4)
. The hole depth must be at least equal to the length of the cramp-irons
(5)
.
2- Fit the flexible hoses through which the electric cables will run so that they lead out of the plate
(3 - 4)
and protrude
from the hole by about 30-40 mm
(5)
.
3- Make sure that the plate is level
(5)
and start filling the hole with concrete.
4- Wait for the concrete to dry.
5- Run the electric cables (for connection of the accessories and electrical power supply) through the flexible
hoses.
To make it easier to make the electrical connections to the control unit, it is advisable to keep a cable length of 400 mm
from the foundation plate hole
(5)
.
EMBEDDING THE PLATE
1- Remove the gearmotor casing by undoing the screws under the side caps
(6)
.
2- Remove the fastening nuts from the plate pins, position the gearmotor on the foundation plate sliding the pins
into the slots on the casing
(7)
. Make sure that the pinion faces the gate.
3- Make the necessary adjustments to level the gearmotor, raising or lowering it by turning the adjusting screws
A(8)
. At first hold the gearmotor raised by 2-4 mm and then lower it after having secured the rack
(8)
.
4- Fit the 4 washers and tighten the 4 nuts to secure the gearmotor parallel to the gate (remember to hold the
gearmotor raised by 2-4 mm)
(8)
.
5- It is recommended to maintain the distances
(8 - 9 - 15)
.
INSTALLING THE GEARMOTOR
1- Manually move the gate to the closed position;
2- unlock the gearmotor (see paragraph Unlocking Device);
3- arrange the rack (optional)
(10 - 11 - 12)
;
4- place the first element of the rack on the pinion in such a way that it protrudes 50 mm from the gearmotor
(13)
creating the space required for the limit switch bracket;
5- secure the element in the slot with a screw (or spacer depending on the type of rack chosen
(10 - 11 - 12)
. It is
advisable to tighten the rack retaining screws at the top of the slot so that the gate can be raised and the
necessary clearance between the rack and pinion maintained should the gate lower;
6- continue fitting the rack, aligning the modules one after another; to properly secure the modules, use a piece of
rack of about 150 mm to allow for tooth timing
(14)
. Once the last module has been secured, cut off the
protruding part with a saw.
7- when all the modules have been fitted, manually carry out various gate opening and closing manoeuvres to
check that it slides smoothly without friction;
8- lower the operator by turning the 4 adjusting screws
A(8)
and lock the gearmotor leaving a clearance of 2 mm
between the pinion and the rack
(15)
to ensure that the weight of the gate does not negatively affect the gearmotor
shaft.
FITTING THE RACK
Each automated device kit for sliding gates contains two limit switches: one to identify the stopping point of the gate
during opening and
closing.
Each limit switch is supplied with the magnet already fitted, identified by the letter "O" for opening and "C" for closing
.
the other one to identify the stopping point of the gate during
(18-21)
FITTING THE LIMIT SWITCHES
If the gate needs to be operated manually, insert the triangular key provided in the dedicated seat on the gearmotor
(22)
and turn it anticlockwise. Manually open or close the gate. To relock the gearmotor, fully turn the triangular key
clockwise. Manually and carefully move the gate until it locks.
Should you wish to replace the unlocking device provided on the gearmotor with an unlocking device with
personalised key, proceed as follows:
1- remove the triangular unlocking key (if inserted);
2- with a star-tip screwdriver undo the screw inside the triangular key unlocking device
(23)
;
3- remove the unlocking device
(24 - 25)
;
4- take the unlocking device with personalised key and fit the two springs in their housings (make sure that the
key is in horizontal position -
26
);
5- Fit the new device in its seat, then press and turn the key 90° anticlockwise
(27)
. Secure the device with the
dedicated pins in the two side holes, exercising slight pressure for better coupling
(28)
.
UNLOCKING DEVICE