UK
UK
The new 24V gearmotor SL 544 allows easily and quickly automating small to medium-sized sliding gates of up to
500Kg.
The automated device with integrated control unit facilitates system certification in accordance with EN125453.
•
Before proceeding with installation, fit a magnetothermal and differential switch with a maximum capacity of 10A
upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening
distance of at least 3mm.
•
All the packaging materials must be kept out of reach of children since they are potential sources of danger.
•
The manufacturer declines all responsibility for proper functioning of the automated device if failing to use original
GIBIDI components and accessories suitable for the intended application.
•
When installation has been completed, always carefully check proper functioning of the system and the devices
used.
•
This instruction manual addresses persons qualified for installation of “live equipment”, therefore, good technical
knowledge is required exercised as profession in compliance with the regulations in force.
•
Maintenance must be performed by qualified personnel.
•
Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
•
This product has been designed and constructed solely for the use indicated in this document. Any other use may
cause damage to the product and be a source of danger.
•
Verify the intended end use and take the necessary safety precautions.
•
Use of the products for purposes different from the intended use has not been tested by the manufacturer and the
operations performed are therefore on full responsibility of the installer.
•
Mark the automated device with visible warning plates.
•
Warn the user that children and animals must not play or stand near the gate.
•
Adequately protect the danger points, for example, using a sensitive frame.
•
Check proper installation of the earthing system; connect all the metal parts of doors, gates, etc. and all the
system components equipped with earthing plate.
•
Exclusively use original spare parts for any maintenance or repair.
•
Do not make any modification to the components of the automated device unless expressly authorised by GIBIDI.
Use adequate cable clamps to ensure proper mechanical connection of the wiring and such that the IP55 degree of
protection of the box is maintained.
INTRODUCTION
WARNINGS FOR THE INSTALLER
In the event of a fault or malfunctioning, disconnect the power supply upstream of the control unit and call technical
service.
Periodically check functioning of the safety devices. Any repairs must be carried out by specialised persons using
original and certified materials.
The product may not be used by children or persons with reduced physical, sensorial or mental abilities, or persons
without experience and knowledge of the product unless correctly instructed.
Do not access the board for adjustments and/or maintenance.
WARNINGS FOR THE USER
1- Gearmotor; 220-230V power supply, 3x1.5mm² cable (comply with the current standards)
2- Photocell transmitter 2x0.5mm² cable
3- Photocell receiver 4x0.5 mm² cable
4- Antenna screened coaxial cable.
5- Frame 4x0.5mm² cable
6- Rack
7- Key selector 3x0.5mm² cable
8- 24 VDC flashing light signaller 2x0.75mm² cable (if 12x0.75 mm² RX cable is present)
9- Omnipolar magnetothermal switch with minimum contact opening of 3 mm Power supply line to the control unit
220-230V, 50-60Hz, 3x1.5 mm² cable (comply with the current standards).
ELECTRICAL EQUIPMENT
TECHNICAL DATA
Supply voltage
Motor power supply
Power absorbed
Current absorbed
Thermal cutout
Pick-up capacitor
Max speed
Maximum torque
Operating temperature
Degree of protection
Operating frequency (%)
Maximum leaf length
Encoder
Operator
Type
Irreversible electromechanical gearmotor
WARNING: IMPORTANT SAFETY INSTRUCTIONS.
It is important for the safety of persons to follow these instructions.
Keep this instruction manual.
Integrated into the motor
SL 544
220/230Vac 50-60Hz
6 m
12 N/m
-20°C + 60°C
IP 55
90% (a 20°C)
-
0,2 m/sec
24Vdc
MAX 100W
MAX 4A
-
14
15
SL
SL
Содержание SL 544
Страница 6: ...SL 6 23 24 25 26 27 28...
Страница 7: ...SL 7 32 31 200 mm 271 mm 322 mm 415 mm 415 mm D E F n 2 M5 x 10 mm A B C 29 30...
Страница 38: ...38 SL NOTES...
Страница 39: ...39 SL NOTES...