Mounting- and Operating Manual GIR 300
page 15 of 34
Switch-contact NPN,
PNP
Counter down
TTL-signal
[O.DN
Switch-contact NPN,
PNP
Interface mode
Serial interface
SER,
Please note:
When changing the measuring mode “InP“, the input signal “SEnS“ and the display-
unit “Unit“ all settings will be changed to factory default. You have to set all the other
settings.
This also regards the settings for offset and slope-adjustment as well as the switching
points!
Parameter Overflow for the available measuring types:
Measuring type
U
I
T.RES T.TC
FREQ
RPN [O.VP [O.DN SER,
Input signal / sensor
X
X
X
X
X
X
X
X
-
Signal edge
-
-
-
-
-
-
X
X
-
Devisor
-
-
-
-
-
X
X
X
-
Input signal low
-
-
-
-
X
-
-
-
-
Input signal high
-
-
-
-
X
-
X
X
-
Decimal point
X
X
X
-
X
X
X
X
-
Display low
X
X
-
-
X
-
-
-
-
Display high
X
X
-
-
X
-
X
X
-
Temperature unit
-
-
X
X
-
-
-
-
-
Limit
X
X
-
-
X
-
X
X
-
Filter
X
X
X
X
X
-
-
-
-
Address
-
-
-
-
-
-
-
-
X
Output
X
X
X
X
X
X
X
X
X