Instrction manual
Intended use
5
1
Intended use
The flowmeter is designed to work with clamp-on transducers to enable the flow of a liquid
within a closed pipe to be measured accurately without needing to insert any mechanical
parts through the pipe wall or protrude into the flow system. Using ultrasonic transit time
techniques, the Portaflow 330 is controlled by a micro-processor system which contains a
wide range of data that enables it to be used with pipes with an outside diameter ranging from
13mm up to 5000mm and constructed of almost any material. The instrument will also
operate over a wide range of fluid temperatures.
The flowmeter can be used to measure clean liquids or oils that have less than 3% by volume
of particulate content. Cloudy liquids such as river water and effluent can be measured along
with cleaner liquids such as demineralised water.
Typical applications
River water
Seawater
Potable water
Demineralised water
Treated water
2
About this document
This document contains all necessary information for the installation, operation and service of
the product.
2.1
Warnings
In this instruction manual, warnings are used, which shall warn you of death, injuries or
material damage. Always read and observe these warnings!
Risk of fatal or serious injury!
There is a risk of fatal or serious physical injury if warnings are ignored!
Risk of damage to property!
Failure to comply leads to a risk of damage to property (loss of time, loss of data, machine
fault etc.)!
Further labels
Symbol Meaning
1.
Call for action in a certain order: Here, you have to do something.
Call for action: Here, you have to do something
Listing
NOTICE
WARNING
CAUTION
Содержание PORTAFLOW 330