Using the Mist Coolant System
CAUTION: The Mist Coolant System has been designed to be
used with Gerber Cool coolant. DO NOT dilute Gerber Cool
prior to use.
CAUTION: Use of other types of fluids may damage the system.
DO NOT use toxic or volatile liquids.
The adjustable drip rate allows for a wide range of mist "wetness"
and cooling capability. The evaporation of the mist provides the
desired cooling effect and minimizes heat build-up of the
remaining lubricant as well.
To use the Mist Coolant System
1.
Turn on the compressor and set the air pressure at 20-40 psi as
indicated on the mist coolant air pressure gage.
To increase air pressure, turn the air pressure regulator
clockwise
.
To decrease air pressure, turn the air pressure regulator
counterclockwise.
2.
Remove the brass filler plug using a flat head screwdriver and
fill the reservoir with Gerber Cool coolant. The reservoir
should remain full to assure proper lubrication. Add coolant
periodically to maintain the level.
3.
Adjust the coolant nozzle so that it is directed at the point of
cutting.
CAUTION: Keep the nozzle at a safe distance to avoid
damaging it with the cutter.
4.
Open the shut off valve near the nozzle coupling mounting
block. When open, the handle is aligned vertically with the
coolant tubing.
Содержание Dimension 200
Страница 10: ...10 Dimension 200 Note The contents of your tool kit may vary from the photograph ...
Страница 12: ...12 Dimension 200 LEG ASSEMBLY ...
Страница 34: ......
Страница 64: ......
Страница 72: ...72 Dimension 200 6 Be sure that the collet and spindle are clean and undamaged ...
Страница 94: ......
Страница 110: ...Weekly Cleaning 100 Z Axis Ways 100 X and Y Axis Ways 101 Electrical Box Air Filter 101 Router Motor Lubrication 102 ...
Страница 111: ......