![Gerber Dimension 200 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/gerber/dimension-200/dimension-200_manual_2216273030.webp)
30
Dimension 200
3.
Insert the 2" diameter hose supplied in the kit on the intake
opening on the table and secure with a hose clamp.
4.
Insert the 2" adapters supplied in the kit on the reducing tee as
shown above.
5.
Insert the 1.5" adapter in the relief valve.
6.
Install the relief valve on the reducing tee as shown above.
7.
Cut the hose to fit in a straight line between the manifold
intake opening and the air filter/relief valve.
8.
Attach the hose to the air filter/relief valve assembly and
secure with a hose clamp.
9.
Attach one end of the remaining hose to the filter exhaust
opening with a 2" barb adapter and secure with a hose clamp.