Operating Principles 61
MOTOR DELAY:
The Motor Delay parameter sets the time the tool will wait for the
router to reach full speed before it descends to the material. Valid
values are 0 to 99 seconds. Gerber recommends a setting of 05
(five seconds).
To change motor delay
1.
Press SELECT while in the STOP READY or STOP JOB mode.
2.
Press the right or left arrow key until
Motor Delay:
appears in
the message box.
3.
Press SELECT to obtain the Motor Delay time.
4.
Press the right or left arrow keys to move the cursor to the
desired digit.
5.
Press the up or down arrow keys to increase or decrease the
digit under the cursor. Acceptable values are 00 to 99.
6.
Press SELECT to save the new value, or RESET to exit without
saving the value.
TEST:
This function allows testing both the router table and the ARC
station to ensure machine accuracy and integrity. The ARC station
does not accept data from the GRAPHIX ADVANTAGE during
testing.
A power-on test restarts the system, displays the revision level of
the system, and repeats orientation of the carriage at the lower left
corner of the table.
The remaining tests are not used by the operator unless instructed
to do so by Gerber technicians.
Содержание Dimension 200
Страница 10: ...10 Dimension 200 Note The contents of your tool kit may vary from the photograph ...
Страница 12: ...12 Dimension 200 LEG ASSEMBLY ...
Страница 34: ......
Страница 64: ......
Страница 72: ...72 Dimension 200 6 Be sure that the collet and spindle are clean and undamaged ...
Страница 94: ......
Страница 110: ...Weekly Cleaning 100 Z Axis Ways 100 X and Y Axis Ways 101 Electrical Box Air Filter 101 Router Motor Lubrication 102 ...
Страница 111: ......