Router Requirements 5
Requirements are as follows:
Electrical Box:
Domestic systems: 200, 208, 220, 230, or 250V AC, 30 amp, 60
Hz, single phase, dedicated line.
NEMA Reference
3-POLE, 4-WIRE
Receptacle: L14-30R
Plug: L14-30P
Export systems: 200, 208, 220, 230, or 250V AC, 20 amp, 50
Hz, single phase, dedicated line.
NEMA Reference
3-POLE, 4-WIRE
Receptacle: L14-20R
Plug: L14-20P
T-Vac Vacuum System:
220V AC, 10 amp, 50/60 Hz, single phase, dedicated line. The
plug and receptacle will be determined by the licensed
industrial electrician at the time of installation.
220V AC, 10 amp, 50/60 Hz, three-phase, dedicated line. The
plug and receptacle will be determined by the licensed
industrial electrician at the time of installation.
X
W
Y
G
Neutral
X
W
G
Y
Neutral, not connected