Operating Principles 43
Power-Up Tests
When the power is turned
ON
, the ARC station performs
diagnostic self-tests, and displays the operating set revision level.
The ARC station requests the operator to slew the router carriage
near the point of orientation, which is the absolute 0,0 point. To
slew to the point of orientation, use the arrow keys to move the
router carriage as far toward the front and to the left as possible.
When the carriage is at 0,0, the carriage will move away from the
limit a preset distance in X and Y. The
ORIENTATION
message will
appear in the display panel, followed by the
STOP READY
message.
If an error occurs:
The system emits a constant audible tone.
Press the RESET key to clear the error and to rerun the failed
test(s).
If the same error recurs or if RAM ERROR, ROM ERROR, or
INTR_ERROR is displayed, contact the Router Support
Department at 800-336-1698 (USA and Canada).
When testing successfully completes, the
STOP READY
message
displays.