Service and Repair Manual
November 2016
Platform Overload Components
90
GS-2669 DC • GS-3369 DC • GS-4069 DC
Part No. 1272220GT
Platform Overload System Troubleshooting
Condition
Possible Cause
Solution
Cannot lift rated load
Relief valve set too low
Increase relief valve pressure
At max. Height with rated load in platform,
pressure switch alarm continues to sound
System needs to be reset
Turn off red emergency stop button,
wait three seconds and turn machine
back on
Max. Height limit switch out of
adjustment or faulty
Lower the up limit switch slightly or
replace contacts
Too much weight in platform
Put correct rated load in platform
Pressure switch out of
adjustment
Turn the pressure switch nut 1/4 turn
into the hydraulic line
Batteries are not fully charged
Charge batteries
Overload system not adjusted
properly
Repeat calibration procedure
Slider channel not lubricated
Lubricate the slider channel
At down limit with rated load in platform, the
pressure switch alarm continues to sound
System needs to be reset
Turn off red emergency stop button,
wait three seconds and turn machine
back on
Down limit switch out of
adjustment
Raise the down limit switch
Too much weight in platform
Put correct rated load in platform
Overload system not adjusted
properly
Turn the pressure switch nut 1/4 turn
into the hydraulic line or repeat
calibration procedure
Содержание GS-2669 DC
Страница 59: ...Service and Repair Manual November 2016 Manifolds 48 GS 2669 DC GS 3369 DC GS 4069 DC Part No 1272220GT...
Страница 134: ...November 2016 Service and Repair Manual 123 Fuse Ground and Platform Control Boxes Fuse Box Layout All Models...
Страница 137: ...Service and Repair Manual November 2016 126 Ground Control Box Layout All Models...
Страница 138: ...November 2016 Service and Repair Manual 127 Platform Control Box Layout Models with 2 Speed Lift...
Страница 141: ...Service and Repair Manual November 2016 130 Platform Control Box Layout Models with Proportional Lift...
Страница 178: ......