Type "HXXX" Faults, continued
DTC
Number
Message on
GCON LCD
Description
Possible Causes
Failure Mode
H089
H089:COILFAULT
OSC LEFT:Open
Open circuit of the oscillate left
circuit.
• Open circuit in oscillate left harness.
• Oscillate left coil open circuit.
• GCON ECM.
All functions inhibited
except platform as long as
machine is in the elevated
position.
If machine is in stowed
position, all functionality is
resumed.
H090
H090:COILFAULT
OSC LEFT:Bat+
Short circuit of the oscillate left
circuit to battery positive.
• Short circuit in oscillate left harness.
• Oscillate left coil short circuit.
• GCON ECM.
All functions inhibited
except platform as long as
machine is in the elevated
position.
If machine is in stowed
position, all functionality is
resumed.
H091
H091:COILFAULT
ACCUM:Bat-
Short circuit of the accumulator
circuit to battery negative.
• Short circuit in accumulator harness.
• Accumulator coil short circuit.
• GCON ECM.
All functions inhibited
except platform as long as
machine is in the elevated
position.
If machine is in stowed
position, all functionality is
resumed.
H092
H092:COILFAULT
ACCUM:Open
Open circuit of the accumulator
circuit.
• Open circuit in accumulator harness.
• Accumulator coil open circuit.
• GCON ECM.
All functions inhibited
except platform as long as
machine is in the elevated
position.
If machine is in stowed
position, all functionality is
resumed.
H093
H093:COILFAULT
ACCUM:Bat+
Short circuit of the accumulator
circuit to battery positive.
• Short circuit in accumulator harness.
• Accumulator coil short circuit.
• GCON ECM.
All functions inhibited
except platform as long as
machine is in the elevated
position.
If machine is in stowed
position, all functionality is
resumed.
H105
H105:COILFAULT
OSC SUPPLY
Short circuit of the oscillate supply
circuit to battery positive/negative or
open circuit.
• Short or open circuit in oscillate supply harness.
• Oscillate supply coil short or open circuit.
• GCON ECM.
All functions inhibited
except platform as long as
machine is in the elevated
position.
If machine is in stowed
position, all functionality is
resumed.
H116
H116:COILFAULT
EXTEND/RETRACT
Short circuit of the outrigger supply
circuit to battery positive/negative or
open circuit.
• Short or open circuit in outrigger harness.
• Outrigger supply coil short or open circuit.
• GCON ECM.
All functions inhibited
except platform as long as
machine is in the elevated
position.
If machine is in stowed
position, all functionality is
resumed.
Содержание GS-2669 DC
Страница 59: ...Service and Repair Manual November 2016 Manifolds 48 GS 2669 DC GS 3369 DC GS 4069 DC Part No 1272220GT...
Страница 134: ...November 2016 Service and Repair Manual 123 Fuse Ground and Platform Control Boxes Fuse Box Layout All Models...
Страница 137: ...Service and Repair Manual November 2016 126 Ground Control Box Layout All Models...
Страница 138: ...November 2016 Service and Repair Manual 127 Platform Control Box Layout Models with 2 Speed Lift...
Страница 141: ...Service and Repair Manual November 2016 130 Platform Control Box Layout Models with Proportional Lift...
Страница 178: ......