background image

Introduction and Specifications

Technical Specifications

076R200-000

SpectraComm IP Router Card

1-9

Issue 2

Installation and Operation Manual

Supported 
Protocols

Frame Relay LMI
(UNI-U)

ITU-T Q.933 Annex A
ANSI T1.617 Annex D
Consortium LMI.

Frame Relay 
IP Encapsulation

RFC 1490 IETF, Cisco (raw), SNAP

Frame Relay PVCs 

Maximum number: 16

Point-to-Point Protocol 
(PPP)

RFC 1661 (1994); STD 51

LAN-X

GDC Proprietary LAN extension 

Ethernet

ANSI/IEEE 802.3; 
Rates: 10 Mbps, 100 Mbps

Compliance &
Compatibility

SC-IP Card

Designed for NEBS Level III Compliance

FCC Part 68 approved; FCC Part 15 approved.

UL Listed; CUL listed. 

Compliance with Bell Pub. 62310 and ANSI T1.410 standards

Table 1-2

SC-IP Specifications (Initial Feature Set)

Item

Specification

Description

Содержание SC-IP

Страница 1: ...6SHFWUD RPP 3 ROUTER CARD Installation Operation Manual 076R200 000 Issue 2 October 2002...

Страница 2: ...rademarks or registered trademarks of their respective companies or organizations Documentation Revision History GDC P N 076R200 000 Related Publications REV is the hardware revision 000 001 etc VREF...

Страница 3: ...plications 1 4 SC IP LAN X Applications 1 5 The SC IP Front Panel 1 6 SC IP Applications with Ethernet Switching 1 7 Technical Specifications 1 8 Chapter 2 Installation Connections Overview 2 1 Unpack...

Страница 4: ...rminal Server Web Screen 4 10 DLCI Web Screen 4 11 LMI Web Screen 4 12 Traffic Shaping 4 13 Appendix A Application Guidelines General Application Information A 1 Command Access Modes A 1 SC IP Default...

Страница 5: ...76R200 000 SpectraComm IP Router Card iii Issue 2 Installation and Operation Manual Table of Contents Example 2 Configuring SC IP for IP Routing PPP B 12 Example 3 Configuring SC IP for LAN X Mode B 1...

Страница 6: ...iv SpectraComm IP Router Card 076R200 000 Installation and Operation Manual Issue 2 Table of Contents...

Страница 7: ...for updated product information or contact your General DataComm field representative General DataComm Inc 6 Rubber Avenue Naugatuck Connecticut USA 06770 Tel 1 203 729 0271 Safety Information This m...

Страница 8: ...ned for that location Never touch uninsulated network wires or terminals unless the network line is disconnected at the network interface Never install network wiring during an electrical storm Antist...

Страница 9: ...phone company FCC Registration Number US AG6DENAN97J Telephone Company jack type RJ48C RJ11C Facility Interface Codes DDS 04DU9 DN BN 1KN 1SN 02LS2 Service Order Code DDS 6 0Y 9 0Y Industry Canada Not...

Страница 10: ...s r parations de mat riel homologu doivent tre coordonn es par un repr sentant d sign par le fournisseur L entreprise de t l communications peut demander l utilisateur de d brancher un appareil la sui...

Страница 11: ...actory Direct Support Repair GDC provides regular and warranty repair services through Factory Direct Support Repair at its U S headquarters in Naugatuck Connecticut This customer support organization...

Страница 12: ...Preface Support Services and Training x SpectraComm IP Router Card 076R200 000 Installation and Operation Manual Issue 2...

Страница 13: ...Ethernet LAN switch SC IP s eight port terminal server can connect to craft ports of co located devices to provide out of band access Typically the SC IP provides connectivity via a T1 port The link l...

Страница 14: ...grated terminal server ports at the shelf rear panel connector for remote access of up to eight devices Allows standards based IP application access Telnet SNMP or HTTP to remote equipment Supports pi...

Страница 15: ...t and the AUX port Craft Console Port The Craft port is used for local configuration and monitoring This EIA 232 interface is fixed as serial async 9600 baud 8 data 1 start stop no parity Ethernet 10...

Страница 16: ...rnet LAN ports or their craft ports The SC IP can be accessed from the NOC over the Carrier s data network using multiple WAN interfaces such as its integral T1 CSU DSU In a future release a synchrono...

Страница 17: ...ducted in one direction from a specified SC IP port While in LAN X mode a SC IP port must be specified for management SC IP in LAN X mode also supports spanning tree protocol to detect and eliminate l...

Страница 18: ...Data frames are present at the T1 Network port T1 RX Off No Receive Data present at the T1 Network port On GREEN Indicates data present at the T1 port originating from the Network AUX TX Future Use O...

Страница 19: ...by breaking up the collision domain thereby dramatically increasing network performance Eliminates unnecessary network traffic by delivering dedicated bandwidth for each port LAN equipment at the remo...

Страница 20: ...Altitude Up to 12 191 m 40 000 ft Operating Temperature 0 to 50 degrees C 32 to 122 degrees F Relative humidity 5 90 non condensing Altitude 60 to 4 000 m 197 to 13 123 ft For altitudes above 1800 m...

Страница 21: ...1490 IETF Cisco raw SNAP Frame Relay PVCs Maximum number 16 Point to Point Protocol PPP RFC 1661 1994 STD 51 LAN X GDC Proprietary LAN extension Ethernet ANSI IEEE 802 3 Rates 10 Mbps 100 Mbps Compli...

Страница 22: ...Introduction and Specifications Technical Specifications 1 10 SpectraComm IP Router Card 076R200 000 Installation and Operation Manual Issue 2...

Страница 23: ...Chapter 3 SC IP Configuration Note The SC IP s LAN X mode and IP forwarding functions are mutually exclusive that is when the SC IP is configured for LAN extension mode the IP routing functions are no...

Страница 24: ...Shelf Manual P N 010R302 000 the SpectraComm 2000 Shelf Manual P N 010R358 000 and the SC 1001 1002 Enclosure Manual P N 010R112 000 Table 2 1 SC IP Equipment Description Connectivity Part Number Spec...

Страница 25: ...Supply Z1 S 16DRJ45 8 Slot Dual RJ45 2 Z3 S 16DB25 16 Slot DB25 Blank Panel Power Supply 010M056 001 010B151 001 035P034 002 010C342 001 010C339 001 010D727 001 MS 2 Mod 7 Mass Term 100 120 Vac MS 2 S...

Страница 26: ...rical connections through the back panel and front panel connectors provided Figure 2 1 SpectraComm Card and Shelf Connections SPECTRACOMM SHELF BACK PANEL SC 2000 SHELF BACK PANEL SC 1001 ENCLOSURE B...

Страница 27: ...a RJ48 connector located on the shelf rear panel at the SC IP slot J33 J48 When enabled as the AUX interface this port supports an asynchronous connection to an external modem When enabled as the seri...

Страница 28: ...rol leads tied to the appropriate state For example a device with a 25 pin terminal connection may need one or more pins driven to the EIA high state Table 2 5 Terminal Server Port Pinouts DTE Interfa...

Страница 29: ...IP Front Panel LAN ports support 10 100BASE T Ethernet connectivity This port requires an RJ45 to RJ45 straight thru or crossover cable GDC S 078H010 XXX or S 078H011 XXX The table below describes Eth...

Страница 30: ...or the Terminal Server DCE cable assemblies Figure 2 2 Terminal Server DTE Cable Pinouts Sheet 1 of 2 BLU WHT WHT BLU ORG WHT 3 1 2 DB25M 1 26 3 DTE INTERFACE CABLE P N 025H502 004 GND RX TX 27 2 28 1...

Страница 31: ...7 18 DB25M 16 41 18 DTE INTERFACE CABLE P N 025H502 004 GND RX TX 42 17 43 16 41 18 TELCO 50 PIN M 1 2 3 4 5 6 7 8 RJ 45 8 POS DTE RS 561 PORT 6 TELCO 50 PIN F HARMONICA BLOCK P N 209 036 034 GRY RED...

Страница 32: ...7 8 RJ 45 8 POS DCE RS 561 PORT 1 TELCO 50 PIN F HARMONICA BLOCK P N 209 036 034 WHT OR GRN WHT WHT GRN 6 5 4 4 29 6 GND RX TX 30 5 31 4 29 6 1 2 3 4 5 6 7 8 RJ 45 8 POS DCE RS 561 PORT 2 BRN WHT WHT...

Страница 33: ...ble 2 8 Y Adapter Cable Pinouts Signal Direction Shelf Connector RJ48 Switched Network RJ11 T1 Line RJ48 T1 Rx Ring From line 1 1 T1 Rx Tip From line 2 2 3 T1 Tx Ring To Line 4 4 T1 Tx Tip To Line 5 5...

Страница 34: ...e rear panel IEC connector and to a wall receptacle that supplies the required AC power 3 Verify that the Front Panel INS LED flashes on and off After a few seconds the LED will illuminate steady 4 Th...

Страница 35: ...ired command arguments The CLI will prompt for any required argument that is missing from a command line Smart CLI Quick Reference Get context sensitive command help by using the character in the CLI...

Страница 36: ...creen will appear followed by a command line prompt W E L C O M E T O S P E C T R A C O M M I P Copyright General DataComm 2002 Running version is T0 0 18 Use at any time on the command line to get he...

Страница 37: ...y in For USER mode the prompt string ends in Commands in USER mode allow viewing but not changing configuration data For SUPERVISOR mode the prompt string ends in Commands in SUPERVISOR mode allow USE...

Страница 38: ...nfigure t1 fdl ANSI T1 403 configure t1 framing ESF configure t1 lbo ds1 0 0dB configure t1 linecode B8ZS configure t1 loopback INHIBIT configure t1 timeslots 1 24 64 Note When configuring the Line Bu...

Страница 39: ...nfigured Type configure frame relay traffic shape serial0 configure frame relay ena traffic serial0 13 Enable Traffic Shaping by typing configure frame relay ena traffic serial0 14 Configure Terminal...

Страница 40: ...1 Network DEVICE 8 DEVICE 5 NETWORK MANAGER ROUTER TYPICAL REMOTE OFFICE T1 MANAGED CRAFT DEVICES LAN DEVICE 2 LAN DEVICE 1 MANAGED LAN DEVICES SPECTRACOMM 2000 SC ES SC IP SC 2000 SHELF orlando_lan 1...

Страница 41: ...by typing configure prompt your_site 3 Configure the T1 values for your network configure t1 clock source line configure t1 fdl ANSI T1 403 configure t1 framing ESF configure t1 lbo ds1 0 0dB configur...

Страница 42: ...on 11 Enable each configured Terminal Server Ports by typing configure term serv enable term 12 Set up static routes for the PPP leased line network by typing configure ip route add serial0 destinatio...

Страница 43: ...SC IP Router in a Typical PPP T1 Network DEVICE 8 DEVICE 5 NETWORK MANAGER ROUTER TYPICAL REMOTE OFFICE T1 MANAGED CRAFT DEVICES LAN DEVICE 2 LAN DEVICE 1 MANAGED LAN DEVICES SPECTRACOMM 2000 SC ES S...

Страница 44: ...gure prompt your_NOC_site 3 Configure the T1 values for your network configure t1 clock source line configure t1 fdl ANSI T1 403 configure t1 framing ESF configure t1 lbo ds1 0 0dB configure t1 lineco...

Страница 45: ...by pinging from your PC workstation at the NOC to equipment at the remote office and vice versa Configure the Remote SC IP 12 Attach the hyperterminal to the craft port of the remote SC IP unit 13 Aft...

Страница 46: ...onfigure lanx router mgt serial0 The second method uses the local SC IP to configure the IP and default route of the remote SC IP Once the LAN X link is up type from the local SC IP configure lanx rou...

Страница 47: ...uting HOST HOST HOST LAN NETWORK MANAGER TYPICAL REMOTE OFFICE LAN ETHERNET0 TYPICAL NOC LAN T1 HOST HOST HOST SERIAL0 LAN General DataComm SC IP General DataComm SC IP LAN X T1 INTERNAL TIMING ETHERN...

Страница 48: ...SC IP Configuration Configuring SC IP with Smart CLI 3 14 SpectraComm IP Router Card 076R200 000 Installation and Operation Manual Issue 2...

Страница 49: ...or craft interface you can toggle http disable enable to clear all cookies Note SC IP uses Java 1 1 If your Browser is Netscape 6 0 Java will not be supported You will need to acquire a Java plug in...

Страница 50: ...rivileges as assigned by an Administrator A valid password can be up to 20 alphanumeric characters If three consecutive invalid passwords are entered a temporary lock out will occur Access Modes Acces...

Страница 51: ...statistics on the selected SC IP interface Command Line Opens a web based CLI interface Set Up Interface Configuration Displays configuration and status of all interfaces except Craft and Terminal Se...

Страница 52: ...iption System Name Location Contact Fields in which the system administrator can enter descriptions at any time up to 32 characters for each field Operating Mode Router Mode or LAN X Mode System Up Ti...

Страница 53: ...terface Statistics Web Screen Field Selection Description Select Interface ethernet0 ether Selects the ethernet port interface modem0 PPP Selects the modem port PPP interface serial0 Selects the seria...

Страница 54: ...ill not be displayed Configuration commands that are restricted to ADMIN mode will not be displayed You must logout of the web interface and make a Telnet or terminal connection in ADMIN mode to acces...

Страница 55: ...able characters can be entered to describe an interface Illegal characters include any non printing characters such as CTRL and ALT Table 4 5 Interface Screen Field Description Interface Displays the...

Страница 56: ...een Field Description IP Address Prefix Displays the IP address configured for destination devices networks or interfaces Next Hop GW Displays the configured IP address of the next hop or gateway addr...

Страница 57: ...Select Line or Internal Framing Select ESF D4 or Auto Line Coding Select B8ZS or AMI Line Buildout Pre equalization Select DS1 Auto Line Buildout DS1 0 0dB Line Buildout DS1 7 5dB Line Buildout DS1 15...

Страница 58: ...ing a port from the list or by selecting a port from the pulldown list The current settings are displayed in the entry fields 2 Make selections and type data in the entry fields for the selected port...

Страница 59: ...ed from data entered at the command line interface For more information refer to Chapter 3 Configuring SC IP with Smart CLI or use the CLI online help provided at the Command Line web screen Table 4 8...

Страница 60: ...Configuration Procedure 1 Activate the entry fields for the desired interface by clicking on the list or by selecting it from the pulldown list The current settings are displayed in the entry fields 2...

Страница 61: ...tion Procedure 1 Activate the entry fields for the desired interface by clicking on the list or by selecting it from the pulldown list The current settings are displayed in the entry fields 2 Configur...

Страница 62: ...The Web Interface SC IP Web Screens 4 14 SpectraComm IP Router Card 076R200 000 Installation and Operation Manual Issue 2...

Страница 63: ...upervisor cannot be used as username logins They are only used to enable the supervisor admin mode The only default username login is defined as gdc with the password gdc This username may be deleted...

Страница 64: ...fault System Prompt SC IP Serial0 Interface Link encapsulation serial0 Frame Relay DTE Inactivity Timer 900 seconds LMI type cisco HTTP Service Disabled LMI n391 6 SNMP Service Disabled LMI n392 3 T1...

Страница 65: ...on which defines the 32 bit IP address in four 8 bit fields or four octets e g 195 88 11 4 Each octet has a value from 000 to 255 Using the traditional Class A B and C network architectures one or mor...

Страница 66: ...nd 256 contiguous Class C networks Table A 3 Network Classification NTWK Class First Octet Range of Networks Default Mask Example Description A 1 126 1 0 0 0 127 0 0 0 255 0 0 0 18 0 172 16 Class A B...

Страница 67: ...sk which further subdivides a standard class address for routing within an organization A station submask indicates the bits used for network identification A sending station checks the bits to see if...

Страница 68: ...eight consecutive zeros with a sequence including bipolar violations which can be detected to allow any combination of zeros and ones to be transmitted throughout the T1 Network When optioned for AMI...

Страница 69: ...lowing commands can then be used on the file Use the batch show command to view the batch script file in the batch queue Use the batch run command to execute the batch script file in the batch queue A...

Страница 70: ...erial0 interface is UP 2 At the command prompt type show int to check that the Line Protocol is UP on all interfaces you intend to use 3 At the command prompt type show ip route to check that you have...

Страница 71: ...lable along with a one line description of each command Demo_unit _______________________SpectraComm IP Commands___________________________ clear Reset functions configure Configure system parameters...

Страница 72: ...Server parameters t1 Configure T1 parameters term serv Configure terminal server parameters When you type configure interfaces the screen displays help for that specific subcommand ___________Help for...

Страница 73: ...xample The full command name configure may be selected by any of the following Demo_unit conf Demo_unit confi Demo_unit config When a space is entered all of the above strings will expand to configure...

Страница 74: ...tures are added to the SC IP For complete and up to date commands use the SC IP s context sensitive help by entering the char acter anywhere in a command string Command Type Command Syntax Details SC...

Страница 75: ...x Description configure accounts add username password Adds Changes username and password to accounts Username and password are each 20 a n chars max configure accounts delete username password Delete...

Страница 76: ...nter x 1 255 default 6 frame relay lmi n392 s n x Configures LMI status response error threshold Sub interface name 1 or 0 N392 counter x 1 10 default 3 frame relay lmi n393 s n x Configures LMI event...

Страница 77: ...ces ip address x n nnn a b c d a b c d Configure interface IP address Interface name x ethernet0 modem0 serialn or serialn nnn IP address a b c d IP mask a b c d Optional IP broadcast address a b c d...

Страница 78: ...elay network Figure B 1 1 Set the system prompt by typing configure prompt orlando_unit 2 Configure the T1 values for your network If the SC IP s T1 default values shown below apply to your network yo...

Страница 79: ...ping configure interfaces add sub serial0 17 configure interfaces description serial0 17 NOC_miami configure interfaces enable serial0 17 8 Map Frame Relay DLCIs IP Encapsulation to sub interfaces by...

Страница 80: ...dd serial0 117 172 16 5 10 255 255 255 255 172 16 5 6 1 16 Set up a static route at the NOC towards a LAN Device 1connected at the Terminal Server port by typing configure ip route add serial0 117 192...

Страница 81: ...ork DEVICE 2 DEVICE 1 DEVICE 8 NETWORK MANAGER ROUTER REMOTE OFFICE Orlando T1 MANAGED CRAFT DEVICES LAN DEVICE 2 LAN DEVICE 1 MANAGED LAN DEVICES SPECTRACOMM 2000 SC ES SC IP SC 2000 SHELF orlando_la...

Страница 82: ...the Ethernet IP address and mask by typing configure interfaces ip address ethernet0 172 16 5 6 255 255 0 0 4 Enter a description of the Ethernet interface by typing configure interfaces description...

Страница 83: ...onnected at the Terminal Server port by typing configure ip route add serial0 192 160 1 12 255 255 255 255 172 16 5 6 1 15 Type disable to turn off the supervisor access 16 Turn Admin mode on by typin...

Страница 84: ...sing PPP Protocol ROUTER DEVICE 2 DEVICE 1 DEVICE 8 NETWORK MANAGER REMOTE OFFICE Orlando T1 MANAGED CRAFT DEVICES LAN DEVICE 2 LAN DEVICE 1 MANAGED LAN DEVICES SPECTRACOMM 2000 SC ES SC IP SC 2000 SH...

Страница 85: ...e t1 lbo ds1 0 0dB configure t1 linecode B8ZS configure t1 loopback INHIBIT configure t1 timeslots 1 24 4 Type show T1 to check the T1 current values Modify if needed 5 Configure and enable the Ethern...

Страница 86: ...t1 lbo ds1 0 0dB configure t1 linecode B8ZS configure t1 loopback INHIBIT configure t1 timeslots 1 24 4 Type show T1 to check the T1 current values Modify if needed 5 Configure and enable the Ethernet...

Страница 87: ...rk HOST HOST HOST LAN NETWORK MANAGER REMOTE OFFICE LAN ETHERNET0 NOC LAN T1 HOST HOST HOST SERIAL0 General DataComm SC IP LAN X T1 INTERNAL TIMING ETHERNET0 SERIAL0 T1 LINE TIMING DEVICE 2 DEVICE 1 D...

Страница 88: ...CLI Reference Configuration Tutorials B 18 SpectraComm IP Router Card 076R200 000 Installation and Operation Manual Issue 2...

Страница 89: ......

Страница 90: ......

Отзывы: