____________________ _
ADL300-EPCv2- User Guide
Page 58 of 64
7. REMOTE CONTROL OR VIA I/O
7.1 Introduction
This section describes how to configure the digital inputs and outputs of the ADL300 drive with EPC
application. It includes an example of I/O connection and another of how to send command signals via
fieldbus.
The source of each signal can, however, always be selected separately using parameters, thus also making
different configurations possible (e.g. Menu 05.05 "Lift Command" or 05.06 "Lift Inputs").
7.2 Example of Control via Digital I/Os
AC
PC
SH
BR
A1
A2
A1
A2
A1
A2
LIFT CONTROLLER
The table below shows the factory settings for this example:
Commands:
Input
Description
Default source
Enable
Enable command
Enable digital input
Floor Call
Floor call command
Dig input 6X
Cycle 0
Zero cycle command
Dig input 4X
Self study
Self study command
Dig input 5X
Jog Fwd
Jog forward command
Dig input 7X
Jog Rev
Jog reverse command
Dig input 8X
Realignment
Realignment command
Dig input 9X
Forward
Forward command
Null
Reverse
Reverse command
Null
Stop
Stop command
Null
Maintenance
Maintenance command
Null