____________________ _
ADL300-EPCv2- User Guide
Page 56 of 64
CONTROL WORD2 (SelLiftWdecInp1):
Bit
Description
Remarks
0
Enable
Enable command
1
Floor Call
Floor call command
2
Cycle 0
Zero cycle command
3
Self study
Self study command
4
Jog Fwd
Jog forward command
5
Jog Rev
Jog reverse command
6
Realignment
Realignment command
7
Forward
Forward command
8
Reverse
Reverse command
9
Stop
Stop command
10
Maintenance
Maintenance command
11
Battery Mode-Run
Battery Mode-Run command
12
Floor 0
Floor command bit 0
13
Floor 1
Floor command bit 1
14
Floor 2
Floor command bit 2
15
Floor 3
Floor command bit 3
Floor command
Bit 3 Bit 2 Bit 1 Bit 0
Floor 0
0
0
0
0
Floor 1
0
0
0
1
Floor 2
0
0
1
0
Floor 3
0
0
1
1
Floor 4
0
1
0
0
Floor 5
0
1
0
1
Floor 6
0
1
1
0
Floor 7
0
1
1
1
Floor 8
1
0
0
0
Floor 9
1
0
0
1
Floor 10
1
0
1
0
Floor 11
1
0
1
1
Floor 12
1
1
0
0
Floor 13
1
1
0
1
Floor 14
1
1
1
0
Floor 15
1
1
1
1
6.6 Outputs
Lift control output signals are connected directly to the PAD parameters according to the table below:
Par.
signal
description
PAD1
LiftEnable
Lift enable command
PAD2
RunCont
Close contactor command
PAD3
UpCont
Up contactor command
PAD4
DownCont
Down contactor command
PAD5
BrakeCont
Brake command
PAD6
LiftDcBrake
DC brake function command
PAD7
Brake2
Brake control signal
PAD8
WdecompOut
Word decomp output
PAD9
LiftStart
Lift start command
PAD10
Floor Number
Floor number
PAD11
Lift status word1 Contains the copy of StatusWord1 (can be selected using
SelLiftStatWord1
)
PAD12
Lift status word2 Contains the copy of StatusWord2 (can be selected using
SelLiftStatWord2
)
PAD13
DestFloor
Destination
PAD14
Ramp Down
Ramp down
PAD15
InputVariable
Connected to the input selector
PAD16
LiftWdecInp
Connected to the LifWDecomp selector
In this mode they can be accessed from the selection lists and thus easily used to configure the relay and
digital outputs of the drive. (see the PADS menu for configuration).