____________________ _
ADL300-EPCv2- User Guide
Page 40 of 64
Setting of the source for the counter feedback input:
“EPC INPUT LIST” see PAR 11500.
Setting of the source for the brake feedback input:
“EPC INPUT LIST” see PAR 11500.
Setting of the source for the Door Open input:
“EPC INPUT LIST” see PAR 11500.
Setting of the source for the Door Feedback input:
“EPC INPUT LIST” see PAR 11500.
Setting of the source for the Control Word 1 input:
0 FieldBus M->S1
1 FieldBus M->S2
2 FieldBus M->S3
3 WComp
4 PAD16
Setting of the source for the Control Word 2 input:
5 FieldBus M->S1
6 FieldBus M->S2
7 FieldBus M->S3
8 WComp
9 PAD16
Setting of the delay time for sending the slowdown signal.
The value of this parameter is used to compensate for the distance covered during the delay time
between the passage of the cabin on the slowdown sensor and receipt of the decelerate command by
the drive. At high speeds this distance can have significant values: e.g. with a cabin travelling at 2 m/s
and a delay time of 30 ms, the distance covered and to be taken into consideration during the
deceleration phase is 6 cm.
Enable encoder freeze
The status of the inputs is displayed as a hexadecimal value, see the description of "Lift control word1"
for the meaning of each bit
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.11 11512
Contactor Fbk sel
ENUM
16
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.12 11514
Brake Fbk sel
ENUM
17
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.13 11516
Door Open sel
ENUM
18
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.14 11518
Door Fbk sel
ENUM
6000
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.15 11530
Control Word 1
ENUM
0
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.16 11532
Control Word 2
ENUM
1
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.17 11534
Delay acq time
ms
INT
0
0
1000
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.18 11538
Abilita Freeze
BIT
ON
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.19 12206
Control Word 1 Mon
UINT32
0
R
FVS