ADL300-EPCv2- User Guide
Page 41 of 64
The status of the inputs is displayed as a hexadecimal value, see the description of "Lift control word2"
for the meaning of each bit
The status of the comand1 inputs are displayed as hexadecimal values:
Par.
signal
description
Bit0
EnableCmd
Bit1
Start FwdCmd
Bit2
Start RevCmd
Bit3
JogFwdCmd
Bit4
JogRevCmd
Bit5
Null
Bit6
ContFbk
Bit7
BrakeFbk
Bit8
DoorOpen
Bit9
DoorFbk
Bit10
EmergencyMode
Bit11
EPCCycle0Cmd
Bit12
UpperLimit
Bit13
LowerLimit
Bit14
EPCSelfStudyCmd
Bit15
EPCFloorCallCmd
The status of the comand2 inputs are displayed as hexadecimal values:
Par.
signal
description
Bit0
EPCForwardCmd
Bit1
EPCReverseCmd
Bit2
LandASt
Bit3
LandBSt
Bit4
UpperLimitSt
Bit5
LowerLimitSt
Bit6
SlowUpperLimitSt
Bit7
SlowLowerLimitSt
Bit8
EPCMaintenanceCmd
Bit9
EPCSelfLevelling
Bit10
BatterySel
Bit11
BatteryRun
Bit12
Null
Bit13
Null
Bit14
Null
Bit15
Null
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.20 12210
Control Word 2 Mon
UINT32
0
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.21 12216
Command lnput mon1
UINT32
0
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.6.22 12218
Command lnput mon2
UINT32
0
R
FVS