ADL300-EPCv2- User Guide
Page 46 of 64
Rephaser alarm status.
05.10 – FLOOR COMMANDS
A digital signal is sent to the Output 3708 (see menu 5.7 INPUT/OUTPUT Outputs Table) in case of
Synchronous motors, and to the bit 11
Lift Status Word
in case of asynchronous motors, when the
elevator go through each floor. In this way is possible to track by a signal the passage of the car through
a floor. The duration of this signal is configurable by this parameter.
Number of floors
Setting of the source for the floor call command:
0 Digital Input
1 Parameter
2 Fieldbus -> MS3
Floor call setting parameter. Active if the floor call source is selected as "Parameter"
The destination floor value is displayed
The number of floors is displayed.
05.11 – STATUS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.9.11
12190
On Speed Limit On
BIT
OFF
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.10.1 11088
IP Signal Time
ms
INT16
100
50
4000
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.10.1 11440
Number of floors
INT16
7
1
15
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.10.2 11442
Floor Call Source
ENUM
0
0
3
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.10.3 11444
Floor call
UINT16
0
1
15
RW
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.10.4 12048
Floor Destination
UINT16
0
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.10.5 12062
Numero Piano
UINT16
0
R
FVS