____________________ _
ADL300-EPCv2- User Guide
Page 47 of 64
The EPC status is displayed. The following values are possible:
0
ready
1
jog forward
2
jog Reverse
3
Zero Cycle
1 of 2
31
Zero Cycle
2 of 2
4
SelfStudy
1 of 2
41
SelfStudy
2 of 2
5
Floor Call
51
floor call reverse
52
floor call Forward
6
Forward
61
Forward command
2 of 3
62
Forward command
3 of 3
7
Reverse
71
reverse command
2 of 3
72
Forward command 3 of 3
8
stop normal
9
Revelling
91-191 revelling floor call reverse
92-192 revelling floor call forward
10
Battery Run
101 Battery Run Reverse
102 Battery Run Forward
Positioning device ready status is displayed.
On if the following condition is true:
vEPCStatus = 0
(ready)
and
ZeroFound
(zero cycle executed)
and
SelfStudyOk
(Self study executed)
and
sysDriveOk = ON
(Drive not in alarm condition)
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.11.1 12146
EPC Status
INT16
0
R
FVS
Menu
Par
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
5.11.2 12148
PosReady
BOOL
OFF
R
FVS