Disassembly
28
Operating Instructions · GEA Index Cleaner Fury 602
Edition 01/08/2016
Main block, nozzle, inlet and indexing unit
Requirement:
The cleaner must have been removed and completely drained and must have
cooled down.
Carry out the following steps:
1.
Unscrew the nozzles (71) and check if they are clear of blockage.
2.
Remove the stream straightener (73) by pushing it out with a steel rod (Ø 6.0 mm).
3.
Use a hex key (a/f 1/8") to remove the set screws (62), then use a pin punch (Ø
3/16") to drift out the cylinder cap pin (79).
4.
Slide the end cap (2) off.
!
The O-ring (26) should be left in place unless damaged.
5.
Undo the sealing screws (58) and O-rings (42) using a spanner (a/f 14.0 mm).
6.
Slide the valve block (9) off the valve spindle (10).
Filter (56) and filter ring (57) are now visible.
7.
Remove filter (56) and filter ring (57) and check for obstructions; clear if necessary.
8.
Remove two control screws (67) using a hex key (a/f 3/16") and check for blockage.
9.
Slide off two O-rings (12), use pliers to remove the split pins (43).
61 55
36
73
71
53
52
51
13
48
50
72
39
65
38
61
55
69
55
61
38
65
39
37
41
34
44
61
55
31
27
74
49
70
35
70
40
74
58
58
42
42
62
62
57
56
9