Installation and Commissioning
Installation
24
Operating Instructions · GEA Index Cleaner Fury 602
Edition 01/08/2016
Installation
Voraussetzung
We generally recommend that a 500
ϻ
m filter/strainer should be installed in the CIP
supply line at the tank cleaner to prevent blockage or damage resulting from foreign
particles. It is the customer‘s responsibility to ensure the suitability of the
strainer/filter retention rating for this particular application.
The cleaner must have a suitable pipe connection for this.
IMPORTANT NOTE
Danger when screwing the cleaner to the fixed pipe via the lower body
Doing so will cause damage to the gears inside the cleaner or jamming of the mecha-
nism
Screw the cylindrical upper body (2) to the pipe (1).
Carry out the following steps:
1.
Hold the cylindrical upper body (2) and carefully screw it onto the pipe (1) until it is
hand-tight.
2.
Use a strap wrench/adjustable spanner on the cylindrical upper body (2) or a suit-
ably sized spanner on the spanner flats (2) provided to screw the cleaner to the
pipe (1).
Done
1