Installation and Commissioning
Installation Dimensions
Notes on Installation
Observe the following points before installing the cleaner:
•
Switch off the power circuit and protect it from unauthorized switch-on.
•
Protect the supply pump for CIP medium against unauthorized switch-on.
•
Shut off the cleaning medium supply line and secure the line against being opened.
There must not be any chemical cleaning medium in the supply line.
•
Make sure that there are no foreign objects in the system.
•
Clean (rinse) the cleaning medium supply line before connecting the cleaner.
•
The electrical installation must be in accordance with the requirements of EN 60079-
14 in areas with explosive gas atmosphere and in accordance with the requirements
of EN 61241-4 in areas with explosive dust atmosphere.
Installation Dimensions
Installation dimensions
The smallest manhole diameter recommended for normal operation is 200mm (8"). The
nozzles must be vertically aligned. Take care to avoid damaging the cleaner.
Dimensions of manhole with vertically aligned nozzles
1.5"
/
/
BSP NPT NPS
321
mm
17
mm
91
mm
200 mm (8")