Installation and Commissioning
Operating Conditions
22
Operating Instructions · GEA Index Cleaner Fury 602
Edition 01/08/2016
Installation and Commissioning
Operating Conditions
The cleaner is driven by the cleaning liquid flowing through it at a suitable pressure and
flow rate. It is essential that the cleaner is supplied with cleaning liquid at the correct
pressure and flow rate for effective operation. The requirements are specified in the
tables below.
The specified pressure is the pressure required at the cleaning head and not at
the pump.
NOTE
The cleaner may only be operated at a maximum pressure of 12 bar. Higher pressures
can destroy the cleaner.
Operating flow rate and pressure requirements for cleaner Fury 602 – 8 mm nozzles
Required flow rate [l/min]
200
225
250
280
Required flow rate [IMPgpm]
44
51
55
62
Required flow rate [USgpm]
53
60
66
74
Required pressure [bar]
4
6
8
10
Required pressure [psi]
56
84
112
140
Throw length [m]
8
11
12
13
Throw length [ft]
26
36
39
42
Operating flow rate and pressure requirements for cleaner Fury 602 – 10 mm nozzles
Required flow rate [l/min]
295
330
380
415
Required flow rate [IMPgpm]
65
73
84
91
Required flow rate [USgpm]
78
87
100
110
Required pressure [bar]
4
6
8
10
Required pressure [psi]
56
84
112
140
Throw length [m]
8
11
12
13
Throw length [ft]
26
36
39
42