Safety
Instructions for the Safe Operation
14
Operating Instructions · GEA Index Cleaner Fury 602
Edition 01/08/2016
Maintenance and Repair
For maintenance and repair, the following principles apply:
•
Observe the intervals specified in the maintenance schedule.
•
Only allow qualified staff to carry out maintenance or repair work on the cleaner.
•
Before starting any maintenance or repair work, the cleaner must be switched off
and secured against being switched back on. Work may only be started once any
residual energy has been discharged.
•
Block access for unauthorized persons. Put up notice signs which draw attention to
the maintenance or repair work going on.
•
Do not climb on the cleaner. Use suitable access aids and working platforms.
•
Wear suitable protective clothing.
•
Only use suitable and undamaged tools to carry out maintenance work.
•
When replacing parts only use approved, fully functional load lifting devices and
lifting accessories which are suitable for the intended purpose.
•
Before setting the unit back into operation refit all safety devices as originally
provided in the factory. Then check that all safety devices are working correctly.
•
Check pipes are firmly secured, also check for leaks and damage.
•
Check that all emergency stop devices are working correctly.
Disassembly
For disassembly, the following principles apply:
•
Only allow qualified staff to disassemble the cleaner.
•
Before starting disassembly, the cleaner must be switched off and secured against
being switched back on. Work may only be started once any residual energy has
been discharged.
•
Disconnect all power and utility lines.
•
Markings, e.g. on lines, must not be removed.
•
Do not climb on the cleaner. Use suitable access aids and working platforms.
•
Mark the lines (if unmarked) prior to disassembly to ensure they are not confused
when re-assembling.
•
Protect open line ends with blind plugs against ingress of dirt.
•
Pack sensitive parts separately.