This section describes the monitoring possibilities of PTP through web interface.
If desired to update Reason Switches web screen automatically, check the Auto
Refresh checkbox on top to perform it. If selected, monitoring web page will be
updated after 3 seconds of the last update automatically.
PTP External Clock Mode:
T1000, S2020 and S2024G switches do not support external clock output. Thus, this information should not be referred.
PTP Clock Configuration:
PTP Clock Configuration demonstrates the PTP clock instances configured at the
switch.
o
Clock instance number. This number is a link which redirects to the
PTP Clock’s Configuration menu.
o
Device Type configured for instance. Allowed values displayed are
P2pTransp, E2eTransp, Ord-Bound, Master Only and Slave only;
o
Port List, divided in check signals per port.
Symbol
shown at a port column means that the port
is a member of the PTP Clock instance related to the row;
No symbol shown at a port column means that the port is
not a member of the PTP Clock instance related to the
row.