GE Reason Switches
Chapter 8
– Monitoring
240
REASON SWITCHES-TM-EN-3
On the top of the web page can be selected which port is required. Information
shown is as follows:
o
Total received frames at that port, including error frames. This
information is divided in all packets, all octets, all unicast, all
multicast, all broadcast and all Pause frames received;
o
Total transmitted frames at that port, including error frames. This
information is divided in all packets, all octets, all unicast, all
multicast, all broadcast and all Pause frames transmitted;
o
Total received frame size counter, which represents all frames
divided by its size. Shown values are 64-bytes frames to 1527-and-
above frames;
o
Total transmitted frame size counter, which represents all frames
divided by its size. Shown values are 64-bytes frames to 1527-and-
above frames;
o
Total Received Queue counters, in packets.
o
Total Transmitted Queue counters, in packets.
o
Total received error counters, in packets, which is divided in: Drop,
CRC/Aligment, Undersize, Oversize, Fragments, Jabber and Filtered.
o
Total transmitted error counters, in packets, which is divided in:
Drop, CRC/Aligment, Undersize, Oversize, Fragments, Jabber and
Filtered.
Содержание T1000
Страница 2: ......
Страница 11: ...Figure 97 T1000 dimensions 298 Figure 98 S2020 and S2024G dimensions 299...
Страница 12: ......
Страница 41: ...Chapter 3 Hardware Design GE Reason Switches REASON SWITCHES TM EN 3 41 Figure 4 S2024G Switch...
Страница 103: ...GE Reason Switches Chapter 4 Functions REASON SWITCHES TM EN 3 103 Figure 64 Data Monitor Flow Network...
Страница 256: ......
Страница 274: ......